Evidence map›Paper›PMID 33270302›Full record

ArticleJournal of veterinary internal medicine2021

Utility of point-of-care lung ultrasound for monitoring cardiogenic pulmonary edema in dogs.

Shane D Murphy, Jessica L Ward, Austin K Viall, Melissa A Tropf, Rebecca L Walton, Jennifer L Fowler, Wendy A Ware, Teresa C DeFrancesco

Open access · goldAbstract read
In one paragraph

Article in Journal of veterinary internal medicine, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
2.0field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 29 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Review
  6. Review
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Shane D MurphyDepartment of Veterinary Clinical Sciences, College of Veterinary Medicine, Iowa State University, Ames, Iowa, USA.
Jessica L WardDepartment of Veterinary Clinical Sciences, College of Veterinary Medicine, Iowa State University, Ames, Iowa, USA.ORCID https://orcid.org/0000-0002-9153-7916
Austin K ViallDepartment of Veterinary Pathology, College of Veterinary Medicine, Iowa State University, Ames, Iowa, USA.
Melissa A TropfDepartment of Veterinary Clinical Sciences, College of Veterinary Medicine, Iowa State University, Ames, Iowa, USA.ORCID https://orcid.org/0000-0002-5264-4903
Rebecca L WaltonDepartment of Veterinary Clinical Sciences, College of Veterinary Medicine, Iowa State University, Ames, Iowa, USA.
Jennifer L FowlerDepartment of Veterinary Clinical Sciences, College of Veterinary Medicine, Iowa State University, Ames, Iowa, USA.
Wendy A WareDepartment of Veterinary Clinical Sciences, College of Veterinary Medicine, Iowa State University, Ames, Iowa, USA.ORCID https://orcid.org/0000-0003-2812-151X
Teresa C DeFrancescoDepartment of Clinical Sciences, College of Veterinary Medicine, North Carolina State University, Raleigh, North Carolina, USA.ORCID https://orcid.org/0000-0002-3663-3323
Iowa State University · USNorth Carolina State University · US

Funding

Iowa State University College of Veterinary Medicine Seed Grant n/a
6 · The paper itself

Abstract

backgroundPoint-of-care lung ultrasound (LUS) is an effective tool to diagnose left-sided congestive heart failure (L-CHF) in dogs via detection of ultrasound artifacts (B-lines) caused by increased lung water. HYPOTHESIS/

objectivesTo determine whether LUS can be used to monitor resolution of cardiogenic pulmonary edema in dogs, and to compare LUS to other indicators of L-CHF control. ANIMALS: Twenty-five client-owned dogs hospitalized for treatment of first-onset L-CHF.

methodsProtocolized LUS, thoracic radiographs (TXR), and plasma N-terminal pro-B-type natriuretic peptide were performed at hospital admission, hospital discharge, and recheck examinations. Lung ultrasound findings were compared between timepoints and to other clinical measures of L-CHF.

resultsFrom time of hospital admission to discharge (mean 19.6 hours), median number of LUS sites strongly positive for B-lines (>3 B-lines per site) decreased from 5 (range, 1-8) to 1 (range, 0-5; P < .001), and median total B-line score decreased from 37 (range, 6-74) to 5 (range, 0-32; P = .002). Lung ultrasound indices remained improved at first recheck (P < .001). Number of strong positive sites correlated positively with respiratory rate (r = 0.52, P = .008) and TXR edema score (r = 0.51, P = .009) at hospital admission. Patterns of edema resolution differed between LUS and TXR, with cranial quadrants showing more significant reduction in B-lines compared to TXR edema score (80% vs 29% reduction, respectively; P = .003). CONCLUSIONS AND CLINICAL IMPORTANCE: Lung ultrasound could be a useful tool for monitoring resolution of pulmonary edema in dogs with L-CHF.

Indexed as

Dog DiseasesPulmonary EdemaAnimalsDogsLungPoint-of-Care SystemsProspective StudiesUltrasonographyB-linescaninelung rocketspoint-of-carepulmonary edema

Identifiers

PMID33270302
PMCPMC7848339
OpenAlexW3107101005

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.