Evidence map›Paper›PMID 33270033›Full record

ArticleJMIR mHealth and uHealth2020

Ambulatory Phonation Monitoring With Wireless Microphones Based on the Speech Energy Envelope: Algorithm Development and Validation.

Chi-Te Wang, Ji-Yan Han, Shih-Hau Fang, Ying-Hui Lai

Open access · goldAbstract read
In one paragraph

Article in JMIR mHealth and uHealth, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.1field-weighted citation impact, top 51% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 3 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 3 institutions in 1 country.

Chi-Te WangDepartment of Otolaryngology Head and Neck Surgery, Far Eastern Memorial Hospital, New Taipei City, Taiwan.ORCID 0000-0002-9999-1291
Ji-Yan HanDepartment of Biomedical Engineering, National Yang-Ming University, Taipei, Taiwan.ORCID 0000-0001-9208-8502
Shih-Hau FangDepartment of Electrical Engineering, Yuan Ze University, Taoyuan, Taiwan.ORCID 0000-0003-1580-0257
Ying-Hui LaiDepartment of Biomedical Engineering, National Yang-Ming University, Taipei, Taiwan.ORCID 0000-0003-4120-7289
National Yang Ming Chiao Tung University · TWNational Science and Technology Council · TWUniversity of Taipei · TW

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundVoice disorders mainly result from chronic overuse or abuse, particularly in occupational voice users such as teachers. Previous studies proposed a contact microphone attached to the anterior neck for ambulatory voice monitoring; however, the inconvenience associated with taping and wiring, along with the lack of real-time processing, has limited its clinical application.

objectiveThis study aims to (1) propose an automatic speech detection system using wireless microphones for real-time ambulatory voice monitoring, (2) examine the detection accuracy under controlled environment and noisy conditions, and (3) report the results of the phonation ratio in practical scenarios.

methodsWe designed an adaptive threshold function to detect the presence of speech based on the energy envelope. We invited 10 teachers to participate in this study and tested the performance of the proposed automatic speech detection system regarding detection accuracy and phonation ratio. Moreover, we investigated whether the unsupervised noise reduction algorithm (ie, log minimum mean square error) can overcome the influence of environmental noise in the proposed system.

resultsThe proposed system exhibited an average accuracy of speech detection of 89.9%, ranging from 81.0% (67,357/83,157 frames) to 95.0% (199,201/209,685 frames). Subsequent analyses revealed a phonation ratio between 44.0% (33,019/75,044 frames) and 78.0% (68,785/88,186 frames) during teaching sessions of 40-60 minutes; the durations of most of the phonation segments were less than 10 seconds. The presence of background noise reduced the accuracy of the automatic speech detection system, and an adjuvant noise reduction function could effectively improve the accuracy, especially under stable noise conditions.

conclusionsThis study demonstrated an average detection accuracy of 89.9% in the proposed automatic speech detection system with wireless microphones. The preliminary results for the phonation ratio were comparable to those of previous studies. Although the wireless microphones are susceptible to background noise, an additional noise reduction function can alleviate this limitation. These results indicate that the proposed system can be applied for ambulatory voice monitoring in occupational voice users.

Indexed as

Speech AcousticsVoice DisordersAlgorithmsHumansPhonationSpeechadaptive thresholdbackground noisedosimetrynoise reductionphonation habitsphonotraumaspeech envelopevoice disorder

Identifiers

PMID33270033
PMCPMC7746501
OpenAlexW3089690064

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.