Evidence map›Paper›PMID 33266595›Full record

ArticleEntropy (Basel, Switzerland)2018

Characterization of Artifact Influence on the Classification of Glucose Time Series Using Sample Entropy Statistics.

David Cuesta-Frau, Daniel Novák, Vacláv Burda, Antonio Molina-Picó, Borja Vargas, Milos Mraz, Petra Kavalkova, Marek Benes, Martin Haluzik

Abstract read
In one paragraph

Article in Entropy (Basel, Switzerland), 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

David Cuesta-FrauTechnological Institute of Informatics, Universitat Politècnica de València, Alcoi Campus, 03801 Alcoi, Spain.ORCID 0000-0002-0076-0515
Daniel NovákDepartment of Cybernetics, Czech Technical University in Prague, 16000 Prague, Czech Republic.
Vacláv BurdaDepartment of Cybernetics, Czech Technical University in Prague, 16000 Prague, Czech Republic.
Antonio Molina-PicóTechnological Institute of Informatics, Universitat Politècnica de València, Alcoi Campus, 03801 Alcoi, Spain.
Borja VargasInternal Medicine Department, Teaching Hospital of Móstoles, 28935 Madrid, Spain.ORCID 0000-0002-5553-8372
Milos MrazDepartment of Diabetes, Diabetes Centre, Institute for Clinical and Experimental Medicine, 14021 Prague, Czech Republic.
Petra KavalkovaDepartment of Medical Biochemistry and Laboratory Diagnostics, General University Hospital, Charles University in Prague 1st Faculty of Medicine, 12108 Prague, Czech Republic.
Marek BenesHepatogastroenterology Department, Transplant centre, Institute for Clinical and Experimental Medicine, 14021 Prague, Czech Republic.
Martin HaluzikDepartment of Diabetes, Diabetes Centre, Institute for Clinical and Experimental Medicine, 14021 Prague, Czech Republic.

Funding

Ministry of Health Czech republic VFN64165
6 · The paper itself

Abstract

This paper analyses the performance of SampEn and one of its derivatives, Fuzzy Entropy (FuzzyEn), in the context of artifacted blood glucose time series classification. This is a difficult and practically unexplored framework, where the availability of more sensitive and reliable measures could be of great clinical impact. Although the advent of new blood glucose monitoring technologies may reduce the incidence of the problems stated above, incorrect device or sensor manipulation, patient adherence, sensor detachment, time constraints, adoption barriers or affordability can still result in relatively short and artifacted records, as the ones analyzed in this paper or in other similar works. This study is aimed at characterizing the changes induced by such artifacts, enabling the arrangement of countermeasures in advance when possible. Despite the presence of these disturbances, results demonstrate that SampEn and FuzzyEn are sufficiently robust to achieve a significant classification performance, using records obtained from patients with duodenal-jejunal exclusion. The classification results, in terms of area under the ROC of up to 0.9, with several tests yielding AUC values also greater than 0.8, and in terms of a leave-one-out average classification accuracy of 80%, confirm the potential of these measures in this context despite the presence of artifacts, with SampEn having slightly better performance than FuzzyEn.

Indexed as

blood glucosefuzzy entropysample entropysignal classification

Identifiers

PMID33266595
PMCPMC7512430

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.