Evidence map›Paper›PMID 33261735›Full record

ArticleMedical engineering & physics2020

Tibiofemoral helical axis of motion during the full gait cycle measured using biplane radiography.

Tom Gale, William Anderst

Abstract read
In one paragraph

Article in Medical engineering & physics, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Wearables-Only Analysis of Muscle and Joint Mechanics: An EMG-Driven Approach.IEEE transactions on bio-medical engineering · 2022
    Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Tom GaleBiodynamics Lab, Department of Orthopaedic Surgery, University of Pittsburgh, 3820 South Water Street, Pittsburgh, PA 15203, USA. Electronic address: thg17@pitt.edu.
William AnderstBiodynamics Lab, Department of Orthopaedic Surgery, University of Pittsburgh, 3820 South Water Street, Pittsburgh, PA 15203, USA.

Funding

A Probabilistic Pose Estimation Algorithm for 3D Motion Capture DataR44HD066831 · NICHD · C-MOTION, INC. · PI SELBIE, W. SCOTT · 2016 to 2017
$958k
NICHD NIH HHS R44 HD066831
6 · The paper itself

Abstract

The helical axis of motion (HAM), which describes the simultaneous multiplanar translations and rotations that occur within a joint, has been proposed as a single measure to characterize dynamic joint function. The objective of this study was to determine the tibiofemoral HAM during 5 discrete phases of gait. Thirty-nine knees from 20 healthy adults were imaged using high-speed biplane radiography during treadmill walking. The primary outcome measures were the intersection of the HAM with the sagittal plane of the femur, and the direction of the HAM. The intersection point translated an average of 12.7 ± 5.5% of femur condyle depth in the anterior-posterior direction and 28.6 ± 13.3% of femur condyle height in the proximal-distal direction during gait. The anterior/posterior and proximal/distal components of the HAM vector were greater during stance (5.6°±3.8° and 11.1°±5.0°, respectively) than during swing (2.0°±1.1° and 6.4°±3.8°, respectively) (p<0.001) reflecting greater coupled rotations during stance. No significant side-to-side differences in intersection point location or HAM orientation were found during any of the 5 phases of gait (max difference 4.1 ± 3.4% of femur condyle depth and 13.1 ± 16.7% of femur condyle height; 12.7°±12.3° proximal/distal and 4.2°±4.5° anterior/posterior direction). Loading significantly affected HAM location and orientation (p<0.001). Knowledge of healthy knee HAM and typical side-to-side differences during gait can serve as a baseline for evaluating knee motion after clinical interventions.

Indexed as

GaitKnee JointAdultBiomechanical PhenomenaFemurHumansRadiographyRange of Motion, ArticularFinite helical axisGaitHelical axis of motionKinematicsKneeScrew home mechanism

Identifiers

PMID33261735
PMCPMC7710980

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.