ArticleSensors (Basel, Switzerland)2020
A Robust Infrared Transducer of an Ultra-Large-Scale Array.
Article in Sensors (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Demonstration of thermal modulation using nanoscale and microscale structures for ultralarge pixel array photothermal transducers.Microsystems & nanoengineering · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
A robust micro-electro-mechanical systems (MEMS) infrared thin film transducer of an ultra-large-scale array was proposed and fabricated on a 4-inch silicon wafer. The silicon substrate and micro cavities were introduced. This novel transducer had excellent mechanical stability, time response, and state-of-the-art pixel scale. It could bear a load of 1700 g and its load pressure was improved by more than 5.24 times and time constant decreased by 50.7% compared to the traditional soft infrared thin film transducer. The array scale of its pixels exceeded 2k × 2k. The simulation and measured results of the transient temperature and radiation intensity were well consistent. Illuminated by a 532 nm laser with a frequency of 50 Hz and 50% duty cycle, the thermal decay time of the proposed transducer was 6.0 ms. A knife-edge image was utilized for spatial resolution test and the full width at half maximum (FWHM) of the proposed transducer was 24% smaller than the traditional soft one. High-resolution infrared images were generated using the proposed robust transducer. These results proved that the robust transducer was promising in infrared image generation.
Indexed as
Identifiers
What OpenQuestion holds