Evidence map›Paper›PMID 33257714›Full record

ArticleScientific reports2020

A robust method for automatic identification of femoral landmarks, axes, planes and bone coordinate systems using surface models.

Maximilian C M Fischer, Sonja A G A Grothues, Juliana Habor, Matías de la Fuente, Klaus Radermacher

Abstract read
In one paragraph

Article in Scientific reports, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Influence of the screw-home mechanism on TT-TG distance: a 3D kinematic simulation study.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2026
    Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Maximilian C M FischerHelmholtz-Institute for Biomedical Engineering, RWTH Aachen University, Pauwelsstr. 20, 52074, Aachen, Germany. m.fischer@hia.rwth-aachen.de.
Sonja A G A GrothuesHelmholtz-Institute for Biomedical Engineering, RWTH Aachen University, Pauwelsstr. 20, 52074, Aachen, Germany.
Juliana HaborHelmholtz-Institute for Biomedical Engineering, RWTH Aachen University, Pauwelsstr. 20, 52074, Aachen, Germany.
Matías de la FuenteHelmholtz-Institute for Biomedical Engineering, RWTH Aachen University, Pauwelsstr. 20, 52074, Aachen, Germany.
Klaus RadermacherHelmholtz-Institute for Biomedical Engineering, RWTH Aachen University, Pauwelsstr. 20, 52074, Aachen, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The identification of femoral landmarks is a common procedure in multiple academic fields. Femoral bone coordinate systems are used particularly in orthopedics and biomechanics, and are defined by landmarks, axes and planes. A fully automatic detection overcomes the drawbacks of a labor-intensive manual identification. In this paper, a new automatic atlas- and a priori knowledge-based approach that processes femoral surface models, called the A&A method, was evaluated. The A&A method is divided in two stages. Firstly, a single atlas-based registration maps landmarks and areas from a template surface to the subject. In the second stage, landmarks, axes and planes that are used to construct several femoral bone coordinate systems are refined using a priori knowledge. Three common femoral coordinate systems are defined by the landmarks detected. The A&A method proved to be very robust against a variation of the spatial alignment of the surface models. The results of the A&A method and a manual identification were compared. No significant rotational differences existed for the bone coordinate system recommended by the International Society of Biomechanics. Minor significant differences of maximally 0.5° were observed for the two other coordinate systems. This might be clinically irrelevant, depending on the context of use and should, therefore, be evaluated by the potential user regarding the specific application. The entire source code of the A&A method and the data used in the study is open source and can be accessed via https://github.com/RWTHmediTEC/FemoralCoordinateSystem .

Indexed as

AlgorithmsAnatomic LandmarksCadaverFemaleFemurHumansImage Processing, Computer-AssistedMaleMiddle AgedModels, AnatomicOrthopedic ProceduresSoftwareSurgery, Computer-AssistedTomography, X-Ray Computed

Identifiers

PMID33257714
PMCPMC7704624

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked