Evidence map›Paper›PMID 33257558›Full record

Observational studyProceedings of the National Academy of Sciences of the United States of America2020

A wireless, skin-interfaced biosensor for cerebral hemodynamic monitoring in pediatric care.

Alina Y Rwei, Wei Lu, Changsheng Wu, Kelia Human, Emily Suen, Daniel Franklin, Monica Fabiani, Gabriele Gratton, Zhaoqian Xie, Yujun Deng and 9 more

Open access · bronzeAbstract readObservational StudyValidation Study
In one paragraph

Observational study in Proceedings of the National Academy of Sciences of the United States of America, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 46 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
46citing papers in PubMed, 1 pooled it
4.8field-weighted citation impact, top 4% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

46 citing papers in PubMed, 1 synthesis or guideline pooled it, 93 citations in OpenAlex.

  1. Pooled it
  2. Review
  3. Article
  4. Article
  5. Article
  6. Review
  7. Review
  8. Review
  9. Review
  10. Review
  11. Review
  12. Review
  13. Review
  14. Analytical solutions for light propagation of LED.Proceedings of the National Academy of Sciences of the United States of America · 2025
    Article
  15. Article
  16. Article
  17. Article
  18. Review
  19. Review
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

19 authors at 6 institutions in 4 countries.

Alina Y RweiQuerrey Simpson Institute for Bioelectronics, Northwestern University, Chicago, IL 60208; a.y.rwei@tudelft.nl DWeese-Mayer@luriechildrens.org jrogers@northwestern.edu.ORCID 0000-0001-6080-579X
Wei LuQuerrey Simpson Institute for Bioelectronics, Northwestern University, Chicago, IL 60208.ORCID 0000-0003-1328-4471
Changsheng WuQuerrey Simpson Institute for Bioelectronics, Northwestern University, Chicago, IL 60208.
Kelia HumanQuerrey Simpson Institute for Bioelectronics, Northwestern University, Chicago, IL 60208.ORCID 0000-0002-3709-5037
Emily SuenQuerrey Simpson Institute for Bioelectronics, Northwestern University, Chicago, IL 60208.
Daniel FranklinQuerrey Simpson Institute for Bioelectronics, Northwestern University, Chicago, IL 60208.
Monica FabianiBeckman Institute, University of Illinois at Urbana-Champaign, Urbana, IL 61801.ORCID 0000-0002-7579-2773
Gabriele GrattonBeckman Institute, University of Illinois at Urbana-Champaign, Urbana, IL 61801.
Zhaoqian XieState Key Laboratory of Structural Analysis for Industrial Equipment, Department of Engineering Mechanics, International Research Center for Computational Mechanics, Dalian University of Technology, 116024 Dalian, China.ORCID 0000-0003-1320-817X
Yujun DengState Key Laboratory of Mechanical System and Vibration, Shanghai Jiao Tong University, 200240 Shanghai, China.
Sung Soo KwakQuerrey Simpson Institute for Bioelectronics, Northwestern University, Chicago, IL 60208.
Lizhu LiDepartment of Electronic Engineering, Tsinghua University, 100084 Beijing, China.
Carol GuQuerrey Simpson Institute for Bioelectronics, Northwestern University, Chicago, IL 60208.
Alanna LiuQuerrey Simpson Institute for Bioelectronics, Northwestern University, Chicago, IL 60208.ORCID 0000-0001-7151-7064
Casey M RandDepartment of Pediatrics, Division of Autonomic Medicine, Center for Autonomic Medicine in Pediatrics, Stanley Manne Children's Research Institute, Ann & Robert H. Lurie Children's Hospital of Chicago, Chicago, IL 60611.
Tracey M StewartDepartment of Pediatrics, Division of Autonomic Medicine, Center for Autonomic Medicine in Pediatrics, Stanley Manne Children's Research Institute, Ann & Robert H. Lurie Children's Hospital of Chicago, Chicago, IL 60611.
Yonggang HuangQuerrey Simpson Institute for Bioelectronics, Northwestern University, Chicago, IL 60208.
Debra E Weese-MayerDepartment of Pediatrics, Division of Autonomic Medicine, Center for Autonomic Medicine in Pediatrics, Stanley Manne Children's Research Institute, Ann & Robert H. Lurie Children's Hospital of Chicago, Chicago, IL 60611; a.y.rwei@tudelft.nl DWeese-Mayer@luriechildrens.org jrogers@northwestern.edu.ORCID 0000-0001-6061-220X
John A RogersQuerrey Simpson Institute for Bioelectronics, Northwestern University, Chicago, IL 60208; a.y.rwei@tudelft.nl DWeese-Mayer@luriechildrens.org jrogers@northwestern.edu.
Northwestern University · USLurie Children's Hospital · USUniversity of Illinois Urbana-Champaign · USDalian University of Technology · CNShanghai Jiao Tong University · CNTsinghua University · CN

Funding

Northwestern University Clinical and Translational Science Institute (NUCATS)UL1TR001422 · NCATS · NORTHWESTERN UNIVERSITY AT CHICAGO · PI D'AQUILA, RICHARD · 2015 to 2023
$56.8M
Northwestern University Clinical and Translational Science Institute (NUCATS)TL1TR001423 · NCATS · NORTHWESTERN UNIVERSITY AT CHICAGO · PI MCCOLLEY, SUSANNA A · 2015 to 2023
$5.0M
Optical measures of cerebral arterial function as predictors of brain and cognitive agingR01AG059878 · NIA · UNIVERSITY OF ILLINOIS AT URBANA-CHAMPAIGN · PI FABIANI, MONICA, GRATTON, GABRIELE · 2018 to 2022
$3.5M
Role of arterial stiffness in the decline of cognitive control in agingRF1AG062666 · NIA · UNIVERSITY OF ILLINOIS AT URBANA-CHAMPAIGN · PI FABIANI, MONICA, GRATTON, GABRIELE · 2019 to 2019
$3.0M
NCATS NIH HHS TL1 TR001423NCATS NIH HHS UL1 TR001422NIA NIH HHS R01 AG059878NIA NIH HHS RF1 AG062666
6 · The paper itself

Abstract

The standard of clinical care in many pediatric and neonatal neurocritical care units involves continuous monitoring of cerebral hemodynamics using hard-wired devices that physically adhere to the skin and connect to base stations that commonly mount on an adjacent wall or stand. Risks of iatrogenic skin injuries associated with adhesives that bond such systems to the skin and entanglements of the patients and/or the healthcare professionals with the wires can impede clinical procedures and natural movements that are critical to the care, development, and recovery of pediatric patients. This paper presents a wireless, miniaturized, and mechanically soft, flexible device that supports measurements quantitatively comparable to existing clinical standards. The system features a multiphotodiode array and pair of light-emitting diodes for simultaneous monitoring of systemic and cerebral hemodynamics, with ability to measure cerebral oxygenation, heart rate, peripheral oxygenation, and potentially cerebral pulse pressure and vascular tone, through the utilization of multiwavelength reflectance-mode photoplethysmography and functional near-infrared spectroscopy. Monte Carlo optical simulations define the tissue-probing depths for source-detector distances and operating wavelengths of these systems using magnetic resonance images of the head of a representative pediatric patient to define the relevant geometries. Clinical studies on pediatric subjects with and without congenital central hypoventilation syndrome validate the feasibility for using this system in operating hospitals and define its advantages relative to established technologies. This platform has the potential to substantially enhance the quality of pediatric care across a wide range of conditions and use scenarios, not only in advanced hospital settings but also in clinics of lower- and middle-income countries.

Indexed as

Biosensing TechniquesAdolescentCerebrovascular CirculationChildChild DevelopmentChild, PreschoolFemaleHemodynamic MonitoringHumansInfantMaleNeurodevelopmental DisordersNeurophysiological MonitoringSpectroscopy, Near-InfraredWearable Electronic DevicesWireless Technologybioelectronicscerebral hemodynamicsnear-infrared spectroscopywearable electronics

Identifiers

PMID33257558
PMCPMC7749320
OpenAlexW3106792237

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.