Evidence map›Paper›PMID 33256395›Full record

ArticleAnalytical chemistry2020

A Versatile Isobaric Tag Enables Proteome Quantification in Data-Dependent and Data-Independent Acquisition Modes.

Xiaobo Tian, Marcel P de Vries, Hjalmar P Permentier, Rainer Bischoff

Open access · hybridAbstract read
In one paragraph

Article in Analytical chemistry, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
2.3field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 27 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Review
  6. Review
  7. Article
  8. Review
  9. Review
  10. Review
  11. Proteome Informatics in Tibetan Sheep (Frontiers in veterinary science · 2022
    Article
  12. Review
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Xiaobo TianDepartment of Analytical Biochemistry and Interfaculty Mass Spectrometry Center, Groningen Research Institute of Pharmacy, University of Groningen, A. Deusinglaan 16, 9713 AV Groningen, The Netherlands.
Marcel P de VriesDepartment of Pediatrics, University Medical Center Groningen, University of Groningen, Hanzeplein 1, 9713 GZ Groningen, The Netherlands.
Hjalmar P PermentierDepartment of Analytical Biochemistry and Interfaculty Mass Spectrometry Center, Groningen Research Institute of Pharmacy, University of Groningen, A. Deusinglaan 16, 9713 AV Groningen, The Netherlands.
Rainer BischoffDepartment of Analytical Biochemistry and Interfaculty Mass Spectrometry Center, Groningen Research Institute of Pharmacy, University of Groningen, A. Deusinglaan 16, 9713 AV Groningen, The Netherlands.ORCID 0000-0001-9849-0121
University of Groningen · NLUniversity Medical Center Groningen · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Quantifying proteins based on peptide-coupled reporter ions is a multiplexed quantitative strategy in proteomics that alleviates the problem of ratio distortion caused by peptide cofragmentation, as commonly observed in other reporter-ion-based approaches, such as TMT and iTRAQ. Data-independent acquisition (DIA) is an attractive alternative to data-dependent acquisition (DDA) due to its better reproducibility. While multiplexed labeling is widely used in DDA, it is rarely used in DIA, presumably because current approaches lead to more complex MS2 spectra, severe ratio distortion, or to a reduction in quantification accuracy and precision. Herein, we present a versatile acetyl-alanine-glycine (Ac-AG) tag that conceals quantitative information in isobarically labeled peptides and reveals it upon tandem MS in the form of peptide-coupled reporter ions. Since the peptide-coupled reporter ion is precursor-specific while fragment ions of the peptide backbone originating from different labeling channels are identical, the Ac-AG tag is compatible with both DDA and DIA. By isolating the monoisotopic peak of the precursor ion in DDA, intensities of the peptide-coupled reporter ions represent the relative ratios between constituent samples, whereas in DIA, the ratio can be inferred after deconvoluting the peptide-coupled reporter ion isotopes. The proteome quantification capability of the Ac-AG tag was demonstrated by triplex labeling of a yeast proteome spiked with bovine serum albumin (BSA) over a 10-fold dynamic range. Within this complex proteomics background, BSA spiked at 1:5:10 ratios was detected at ratios of 1.00:4.87:10.13 in DDA and 1.16:5.20:9.64 in DIA.

Indexed as

Mass SpectrometryGlycineLimit of DetectionProteomicsSerum Albumin, BovineStaining and LabelingGlycineSerum Albumin, Bovine

Identifiers

PMID33256395
PMCPMC7745205
OpenAlexW3109240557

What OpenQuestion holds

Textmetadata