ArticleAnalytical chemistry2020
A Versatile Isobaric Tag Enables Proteome Quantification in Data-Dependent and Data-Independent Acquisition Modes.
Article in Analytical chemistry, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
13 citing papers in PubMed, 27 citations in OpenAlex.
- Implementation of Nonisobaric TMT Analogs for Accurate Precursor-Level Quantification by plexDIA.Rapid communications in mass spectrometry : RCM · 2026Article
- Accurate quantification in proteomics with QuantUMS.Nature biotechnology · 2026Article
- Multiplexed Data-Independent Acquisition-Based Proteomics Enabled by TMTpro Complementary Ions.Analytical chemistry · 2025Article
- A Tutorial Review of Labeling Methods in Mass Spectrometry-Based Quantitative Proteomics.ACS measurement science au · 2024Review
- Instrumentation at the Leading Edge of Proteomics.Analytical chemistry · 2024Review
- A review of the current state of single-cell proteomics and future perspective.Analytical and bioanalytical chemistry · 2023Review
- Robust dimethyl-based multiplex-DIA doubles single-cell proteome depth via a reference channel.Molecular systems biology · 2023Article
- Strategies for Increasing the Depth and Throughput of Protein Analysis by plexDIA.Journal of proteome research · 2023Review
- Chemical isotope labeling for quantitative proteomics.Mass spectrometry reviews · 2023Review
- Review
- Proteome Informatics in Tibetan Sheep (Frontiers in veterinary science · 2022Article
- Developing mass spectrometry for the quantitative analysis of neuropeptides.Expert review of proteomics · 2021Review
- The Isotopic Ac-IP Tag Enables Multiplexed Proteome Quantification in Data-Independent Acquisition Mode.Analytical chemistry · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Quantifying proteins based on peptide-coupled reporter ions is a multiplexed quantitative strategy in proteomics that alleviates the problem of ratio distortion caused by peptide cofragmentation, as commonly observed in other reporter-ion-based approaches, such as TMT and iTRAQ. Data-independent acquisition (DIA) is an attractive alternative to data-dependent acquisition (DDA) due to its better reproducibility. While multiplexed labeling is widely used in DDA, it is rarely used in DIA, presumably because current approaches lead to more complex MS2 spectra, severe ratio distortion, or to a reduction in quantification accuracy and precision. Herein, we present a versatile acetyl-alanine-glycine (Ac-AG) tag that conceals quantitative information in isobarically labeled peptides and reveals it upon tandem MS in the form of peptide-coupled reporter ions. Since the peptide-coupled reporter ion is precursor-specific while fragment ions of the peptide backbone originating from different labeling channels are identical, the Ac-AG tag is compatible with both DDA and DIA. By isolating the monoisotopic peak of the precursor ion in DDA, intensities of the peptide-coupled reporter ions represent the relative ratios between constituent samples, whereas in DIA, the ratio can be inferred after deconvoluting the peptide-coupled reporter ion isotopes. The proteome quantification capability of the Ac-AG tag was demonstrated by triplex labeling of a yeast proteome spiked with bovine serum albumin (BSA) over a 10-fold dynamic range. Within this complex proteomics background, BSA spiked at 1:5:10 ratios was detected at ratios of 1.00:4.87:10.13 in DDA and 1.16:5.20:9.64 in DIA.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.