ReviewJournal of personalized medicine2020
Visualization and Measurements of Blood Cells Flowing in Microfluidic Systems and Blood Rheology: A Personalized Medicine Perspective.
Review in Journal of personalized medicine, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
18 citing papers in PubMed, 42 citations in OpenAlex.
- Flavonoids: Hemorheological effects and mechanisms of action.Naunyn-Schmiedeberg's archives of pharmacology · 2026Review
- Review
- Insights into Tear Viscosity: A Study of 240 Volunteers.Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2026Article
- Research Progress in In Vitro Screening Techniques for Natural Antithrombotic Medicines.Pharmaceuticals (Basel, Switzerland) · 2025Review
- The Impact of Targeted Therapies on Red Blood Cell Aggregation in Patients with Chronic Lymphocytic Leukemia Evaluated Using Software Image Flow Analysis.Micromachines · 2025Article
- A single-particle mechanofluorescent sensor.Nature communications · 2024Article
- In-depth Exploration of the Basics of Microfluidic Cell Deformability to Unveil its Applications in the Modern Era.Current pharmaceutical design · 2024Article
- Microfluidic Blood Separation: Key Technologies and Critical Figures of Merit.Micromachines · 2023Review
- Microfluidic Microcirculation Mimetic for Exploring Biophysical Mechanisms of Chemotherapy-Induced Metastasis.Micromachines · 2023Article
- A review on non-Newtonian fluid models for multi-layered blood rheology in constricted arteries.Archive of applied mechanics = Ingenieur-Archiv · 2023Review
- Microfluidic Systems for Blood and Blood Cell Characterization.Biosensors · 2022Review
- Diagnosis Methods for COVID-19: A Systematic Review.Micromachines · 2022Review
- Organ-on-a-Chip Platforms for Drug Screening and Delivery in Tumor Cells: A Systematic Review.Cancers · 2022Review
- Properties and Applications of PDMS for Biomedical Engineering: A Review.Journal of functional biomaterials · 2021Review
- Computational Simulations in Advanced Microfluidic Devices: A Review.Micromachines · 2021Review
- Blood Particulate Analogue Fluids: A Review.Materials (Basel, Switzerland) · 2021Review
- Characterization of Nanoparticle Adsorption on Polydimethylsiloxane-Based Microchannels.Sensors (Basel, Switzerland) · 2021Article
- Fabrication and Applications of Microfluidic Devices: A Review.International journal of molecular sciences · 2021Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 4 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Hemorheological alterations in the majority of metabolic diseases are always connected with blood rheology disturbances, such as the increase of blood and plasma viscosity, cell aggregation enhancement, and reduction of the red blood cells (RBCs) deformability. Thus, the visualizations and measurements of blood cells deformability flowing in microfluidic devices (point-of-care devices) can provide vital information to diagnose early symptoms of blood diseases and consequently to be used as a fast clinical tool for early detection of biomarkers. For instance, RBCs rigidity has been correlated with myocardial infarction, diabetes mellitus, hypertension, among other blood diseases. In order to better understand the blood cells behavior in microfluidic devices, rheological properties analysis is gaining interest by the biomedical committee, since it is strongly dependent on the interactions and mechanical cells proprieties. In addition, the development of blood analogue fluids capable of reproducing the rheological properties of blood and mimic the RBCs behavior at in vitro conditions is crucial for the design, performance and optimization of the microfluidic devices frequently used for personalized medicine. By combining the unique features of the hemorheology and microfluidic technology for single-cell analysis, valuable advances in personalized medicine for new treatments and diagnosis approach can be achieved.
Indexed as
Identifiers
What OpenQuestion holds