Evidence map›Paper›PMID 33252333›Full record

ArticleDiagnostic and interventional radiology (Ankara, Turkey)2021

Computational evaluation of inferior vena cava filters through computational fluid dynamics methods.

Anand Rajan, Mina S Makary, Thomas D Martyn, Joshua D Dowell

Open access · bronzeAbstract read
In one paragraph

Article in Diagnostic and interventional radiology (Ankara, Turkey), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.3field-weighted citation impact, top 37% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 4 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 3 institutions in 1 country.

Anand RajanDivision of Vascular and Interventional Radiology, Department of Radiology, The Ohio State University Wexner Medical Center, Columbus, Ohio, USA.
Mina S MakaryDivision of Vascular and Interventional Radiology, Department of Radiology, The Ohio State University Wexner Medical Center, Columbus, Ohio, USA.
Thomas D MartynGE Aviation, Engineering Division, Lynn, Massachusetts, USA.
Joshua D DowellNorthwest Radiology and St. Vincent Health, Indianapolis, Indiana, USA.
The Ohio State University Wexner Medical Center · USSaint Vincent Health System · USSociety of Interventional Radiology · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Numerical simulation is growing in its importance toward the design, testing and evaluation of medical devices. Computational fluid dynamics and finite element analysis allow improved calculation of stress, heat transfer, and flow to better understand the medical device environment. Current research focuses not only on improving medical devices, but also on improving the computational tools themselves. As methods and computer technology allow for faster simulation times, iterations and trials can be performed faster to collect more data. Given the adverse events associated with long-term inferior vena cava (IVC) filter placement, IVC filter design and device evaluation are of paramount importance. This work reviews computational methods used to develop, test, and improve IVC filters to ultimately serve the needs of the patient.

Indexed as

Vena Cava FiltersComputer SimulationDevice RemovalHumansHydrodynamicsVena Cava, Inferior

Identifiers

PMID33252333
PMCPMC7837720
OpenAlexW3106889201

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked