ArticleOperative Orthopadie und Traumatologie2021
Role of a spanning plate as an internal fixator in complex distal radius fractures.
Article in Operative Orthopadie und Traumatologie, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 1 synthesis or guideline pooled it, 16 citations in OpenAlex.
- Temporary spanning plate wrist fixation of complex distal radius fractures: a systematic review of 353 patients.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2022Pooled it
- Early return to cycling after dorsal spanning plate fixation for distal radius fracture in a KEIRIN athlete: a case report.Annals of medicine and surgery (2012) · 2026Article
- Dual Plating and Dorsal Bridge Plating for Comminuted Distal Radius Fractures: A Systematic Review.Journal of clinical medicine · 2026Review
- Distal Radioulnar Joint Dislocation Following Radius Bridging Plate for DRF.Journal of wrist surgery · 2026Article
- Outcomes in Dorsal Spanning Plates for the Management of Distal Radius Fractures.Journal of hand surgery global online · 2025Article
- Bridge Plate Distraction for Complex Distal Radius Fractures: A Cohort Study and Systematic Review of the Literature.Journal of wrist surgery · 2024Article
- [Wrist surgery].Operative Orthopadie und Traumatologie · 2023Article
- The spanning plate as an internal fixator in complex distal radius fractures: a prospective cohort study.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2022Article
- Lessons learned with the Cobra prosthesis in elderly patients with complex distal radius fractures-a retrospective follow-up study.Archives of orthopaedic and trauma surgery · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectiveMinimally invasive temporary internal wrist arthrodesis as an alternative treatment method in complex distal radius fractures. INDICATIONS: Complex distal radius fractures with dorsal and/or palmar comminution and little to no reconstruction possibilities, radiocarpal ligamentous injury, need for early weight bearing through the affected wrist (walking aids). CONTRAINDICATIONS: Complex hand injuries limiting the possibility to safely secure the plate at either the metacarpal or the radial shaft. SURGICAL TECHNIQUE: Percutaneous or open reduction and fixation of the distal radius fracture. Determine the location for the two stab incisions under fluoroscopy; one over the distal radial diaphysis and one over the second or third metacarpal. A third incision over Lister's tubercle allows transposition of the extensor pollicis longus (EPL) tendon, excision of the posterior interosseous nerve and dorsal arthrotomy. Retrograde insertion of the spanning plate. Placement of a first nonlocking screw through the glide hole into the metacarpal shaft. Under traction, a proximal screw hole is filled with a nonlocking screw into the radial diaphysis. Tightening of the cortical screws under lateral fluoroscopic view. The remaining screw holes at both the distal and proximal ends of the plate are filled with locking screws. Layered wound closure. POSTOPERATIVE MANAGEMENT: A removable wrist splint is worn during 2 weeks. Weight bearing through the injured wrist is immediately allowed. Removal of the spanning plate is scheduled at 3 months after radiographic evidence of fracture consolidation.
resultsIn total, twelve distal radius fractures were treated by dorsal spanning plate fixation between January 2018 and January 2019. Average age was 53.3 ± 24.5 years (range 22-95 years). Both 3.5 mm and 2.4/2.7 mm plates were used. All twelve fractures were healed after 3 months. The mean Disabilities of Arm, Shoulder and Hand (DASH) score was 36.4 (range 8.3-70.0). There was one EPL tendon rupture, one case with extensor tendon adhesions, one periosteosynthetic fracture of the radial shaft and one complex regional pain syndrome. There was no implant failure and no infection.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.