Evidence map›Paper›PMID 33244745›Full record

ArticleAnnals of nuclear medicine2021

Non-local mean denoising using multiple PET reconstructions.

Hossein Arabi, Habib Zaidi

Abstract read
In one paragraph

Article in Annals of nuclear medicine, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 19 papers.

0numbers the graph read from it
0cells of the map it votes in
19citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

19 citing papers in PubMed.

  1. Phantom-based optimization of [Annals of nuclear medicine · 2026
    Article
  2. Patlak-Guided Self-Supervised Learning for Dynamic PET Denoising.IEEE transactions on radiation and plasma medical sciences · 2026
    Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Review
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Hossein ArabiDivision of Nuclear Medicine and Molecular Imaging, Department of Medical Imaging, Geneva University Hospital, 1211, Geneva 4, Switzerland.
Habib ZaidiDivision of Nuclear Medicine and Molecular Imaging, Department of Medical Imaging, Geneva University Hospital, 1211, Geneva 4, Switzerland. habib.zaidi@hcuge.ch.ORCID http://orcid.org/0000-0001-7559-5297

Funding

Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung SNRF 320030_176052
6 · The paper itself

Abstract

objectivesNon-local mean (NLM) filtering has been broadly used for denoising of natural and medical images. The NLM filter relies on the redundant information, in the form of repeated patterns/textures, in the target image to discriminate the underlying structures/signals from noise. In PET (or SPECT) imaging, the raw data could be reconstructed using different parameters and settings, leading to different representations of the target image, which contain highly similar structures/signals to the target image contaminated with different noise levels (or properties). In this light, multiple-reconstruction NLM filtering (MR-NLM) is proposed, which relies on the redundant information provided by the different reconstructions of the same PET data (referred to as auxiliary images) to conduct the denoising process.

methodsImplementation of the MR-NLM approach involved the use of twelve auxiliary PET images (in addition to the target image) reconstructed using the same iterative reconstruction algorithm with different numbers of iterations and subsets. For each target voxel, the patches of voxels at the same location are extracted from the auxiliary PET images based on which the NLM denoising process is conducted. Through this, the exhaustive search scheme performed in the conventional NLM method to find similar patches of voxels is bypassed. The performance evaluation of the MR-NLM filter was carried out against the conventional NLM, Gaussian and bilateral post-reconstruction approaches using the experimental Jaszczak phantom and 25 whole-body PET/CT clinical studies.

resultsThe signal-to-noise ratio (SNR) in the experimental Jaszczak phantom study improved from 25.1 when using Gaussian filtering to 27.9 and 28.8 when the conventional NLM and MR-NLM methods were applied (p value < 0.05), respectively. Conversely, the Gaussian filter led to quantification bias of 35.4%, while NLM and MR-NLM approaches resulted in a bias of 32.0% and 31.1% (p value < 0.05), respectively. The clinical studies further confirm the superior performance of the MR-NLM method, wherein the quantitative bias measured in malignant lesions (hot spots) decreased from - 12.3 ± 2.3% when using the Gaussian filter to - 3.5 ± 1.3% and - 2.2 ± 1.2% when using the NLM and MR-NLM approaches (p value < 0.05), respectively.

conclusionThe MR-NLM approach exhibited promising performance in terms of noise suppression and signal preservation for PET images, thus translating into higher SNR compared to the conventional NLM approach. Despite the promising performance of the MR-NLM approach, the additional computational burden owing to the requirement of multiple PET reconstruction still needs to be addressed.

Indexed as

AgedAlgorithmsBody WeightComputer SimulationHumansImage Processing, Computer-AssistedLiverMiddle AgedPhantoms, ImagingSignal-To-Noise RatioTomography, Emission-Computed, Single-PhotonFilteringImage qualityIterative reconstructionNon-local meansPET

Identifiers

PMID33244745
PMCPMC7895794

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.