Evidence map›Paper›PMID 33244446›Full record

ArticleTranslational vision science & technology2020

Improvements in Test-Retest Variability of Static Automated Perimetry by Censoring Results With Low Sensitivity in Retinitis Pigmentosa.

Ava K Bittner, Anushka Mistry, Leon Nehmad, Rakin Khan, Gislin Dagnelie

Open access · goldAbstract read
In one paragraph

Article in Translational vision science & technology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
0.4field-weighted citation impact, top 39% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 10 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Ava K BittnerDepartment of Ophthalmology, Stein Eye Institute, University of California, Los Angeles, Los Angeles, CA, USA.
Anushka MistryCollege of Optometry, Nova Southeastern University, Fort Lauderdale, FL, USA.
Leon NehmadCollege of Optometry, Nova Southeastern University, Fort Lauderdale, FL, USA.
Rakin KhanCollege of Optometry, Nova Southeastern University, Fort Lauderdale, FL, USA.
Gislin DagnelieDepartment of Ophthalmology, Wilmer Eye Institute, Johns Hopkins University, Baltimore, MD, USA.
Nova Southeastern University · USJohns Hopkins University · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: We evaluated whether omitting (censoring) points in more severely damaged visual field areas can reduce test-retest variability of static automated perimetry (SAP) in retinitis pigmentosa (RP), as variability creates a significant challenge when monitoring for changes. Methods: Cohort 1 included 27 eyes in 16 RP subjects with visual acuity (VA) ranging from 20/20 to 20/70 who completed Humphrey 10-2 size III SAP, once per visit at three visits. Cohort 2 included 15 eyes in nine RP subjects with VA ≤ 20/60 who completed Humphrey 30-2 size V SAP, twice per visit at three visits. Variability was assessed using 95% coefficient of repeatability (CR) calculations for uncensored (all threshold values and data points included) and censored data. Results: In cohort 1, the uncensored between-visit 95% CR was 11.6 decibels (dB); censoring locations with threshold values of <8 to 20 dB resulted in 31% to 53% reductions in the 95% CR. For cohort 2, uncensored 95% CRs were 8.7 and 8.0 dB for within- and between-visit variability, respectively; censoring <8 to 17 dB resulted in 15% to 41% and 15% to 43% reductions in within-visit and between-visit 95% CRs, respectively. For both cohorts, censoring at higher values yielded slightly less variability, at the expense of discarding data from a greater number of eyes and test locations. Conclusions: For 20/20 to 20/70 VA tested with size III stimuli, censoring lower sensitivity values results in substantially lower test-retest variability, which may help detect true changes for locations without severe baseline loss. Translational Relevance: A rule of thumb for clinical practices using SAP to monitor RP is that longitudinal losses of >9 dB for individual test locations with initial values ≥ 9 dB are likely to be real and meaningful, as they exceed typical variability.

Indexed as

Retinitis PigmentosaVisual Field TestsEyeHumansVisual AcuityVisual Fieldsperimetryreliabilityretinitis pigmentosavariabilityvisual field

Identifiers

PMID33244446
PMCPMC7683849
OpenAlexW3104526794

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.