Evidence map›Paper›PMID 33244048›Full record

ArticleScientific reports2020

A novel noninvasive approach for evaluating work of breathing indices in a developmental rat model using respiratory inductance plethysmography.

Yan Zhu, Zubair H Aghai, Suhita Gayen Nee Betal, Michael Favara, Gina Fong, Tariq Rahman, Thomas H Shaffer

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact, top 84% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Yan ZhuDepartment of Biomedical Research and Center for Pediatric Lung Research, Nemours/Alfred I. duPont Hospital for Children, P.O. Box 269, Wilmington, DE, 19803, USA.
Zubair H AghaiDepartment of Biomedical Research and Center for Pediatric Lung Research, Nemours/Alfred I. duPont Hospital for Children, P.O. Box 269, Wilmington, DE, 19803, USA.
Suhita Gayen Nee BetalDepartment of Biomedical Research and Center for Pediatric Lung Research, Nemours/Alfred I. duPont Hospital for Children, P.O. Box 269, Wilmington, DE, 19803, USA.
Michael FavaraPediatrics and Neonatology, Sidney Kimmel Medical College at Thomas Jefferson University, Philadelphia, PA, USA.
Gina FongPediatrics and Neonatology, Sidney Kimmel Medical College at Thomas Jefferson University, Philadelphia, PA, USA.
Tariq RahmanDepartment of Biomedical Research and Center for Pediatric Lung Research, Nemours/Alfred I. duPont Hospital for Children, P.O. Box 269, Wilmington, DE, 19803, USA.
Thomas H ShafferDepartment of Biomedical Research and Center for Pediatric Lung Research, Nemours/Alfred I. duPont Hospital for Children, P.O. Box 269, Wilmington, DE, 19803, USA. thomas.shaffer@nemours.org.
Alfred I. duPont Hospital for Children · USThomas Jefferson University · US

Funding

Center for Pediatric Research Pilot ProgramP30GM114736 · NIGMS · NEMOURS CHILDREN'S HOSPITAL, DELAWARE · PI SHAFFER, THOMAS H · 2015 to 2019
$5.1M
NIGMS NIH HHS NIH COBRE P30GM114736NIGMS NIH HHS P30 GM114736
6 · The paper itself

Abstract

Pulmonary function testing (PFT) is an important component for evaluating the outcome of experimental rodent models of respiratory diseases. Respiratory inductance plethysmography (RIP) provides a noninvasive method of PFT requiring minimal cooperation. RIP measures work of breathing (WOB) indices including phase angle (Ф), percent rib cage (RC %), breaths per minute (BPM), and labored breathing index (LBI) on an iPad. The aim of this study was to evaluate the utility of a recently developed research instrument, pneuRIP, for evaluation of WOB indices in a developmental rat model. Sprague Dawley rats (2 months old) were commercially acquired and anaesthetised with isoflurane. The pneuRIP system uses two elastic bands: one band (RC) placed around the rib cage under the upper armpit and another band (AB) around the abdomen. The typical thoracoabdominal motion (TAM) plot showed the abdomen and rib cage motion in synchrony. The plots of phase angle and LBI as a function of data point number showed that values were within the range. The distribution for phase angle and LBI was within a narrow range. pneuRIP testing provided instantaneous PFT results. This study demonstrated the utility of RIP as a rapid, noninvasive approach for evaluating treatment interventions in the rodent model.

Indexed as

AbdomenAnimalsChildHumansInfantIsofluraneLungModels, AnimalMovementPlethysmographyRatsRats, Sprague-DawleyRespirationRespiratory Function TestsRespiratory MechanicsWork of BreathingIsoflurane

Identifiers

PMID33244048
PMCPMC7691344
OpenAlexW3107437323

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.