ArticleWorld journal of radiology2020

Cardiac functional magnetic resonance imaging at 7T: Image quality optimization and ultra-high field capabilities.

El-Sayed H Ibrahim, V Emre Arpinar, L Tugan Muftuler, Jadranka Stojanovska, Andrew S Nencka, Kevin M Koch

Abstract read
In one paragraph

Article in World journal of radiology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

El-Sayed H IbrahimDepartment of Radiology, Medical College of Wisconsin, Milwaukee, WI 53226, United States. eibrahim@mcw.edu.
V Emre ArpinarDepartment of Radiology, Medical College of Wisconsin, Milwaukee, WI 53226, United States.
L Tugan MuftulerDepartment of Neurosurgery, Medical College of Wisconsin, Milwaukee, WI 53226, United States.
Jadranka StojanovskaDepartment of Radiology, University of Michigan, Ann Arbor, MI 48109, United States.
Andrew S NenckaDepartment of Radiology, Medical College of Wisconsin, Milwaukee, WI 53226, United States.
Kevin M KochDepartment of Radiology, Medical College of Wisconsin, Milwaukee, WI 53226, United States.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

background7T cardiac magnetic resonance imaging (MRI) introduces several advantages, as well as some limitations, compared to lower-field imaging. The capabilities of ultra-high field (UHF) MRI have not been fully exploited in cardiac functional imaging.

aimTo optimize 7T cardiac MRI functional imaging without the need for conducting B1 shimming or subject-specific tuning, which improves scan efficiency. In this study, we provide results from phantom and

methodsWe investigated the effects of adding a dielectric pad at different locations next to the imaged region of interest on improving image quality in subjects with different body habitus. We also investigated the effects of adjusting the imaging flip angle in cine and tagging sequences on improving image quality, B1 field homogeneity, signal-to-noise ratio (SNR), blood-myocardium contrast-to-noise ratio (CNR), and tagging persistence throughout the cardiac cycle.

resultsThe results showed the capability of achieving improved image quality with high spatial resolution (0.75 mm × 0.75 mm × 2 mm), high temporal resolution (20 ms), and increased tagging persistence (for up to 1200 ms cardiac cycle duration) at 7T cardiac MRI after adjusting scan set-up and imaging parameters. Adjusting the imaging flip angle was essential for achieving optimal SNR and myocardium-to-blood CNR. Placing a dielectric pad at the anterior left position of the chest resulted in improved B1 homogeneity compared to other positions, especially in subjects with small chest size.

conclusionImproved regional and global cardiac functional imaging can be achieved at 7T MRI through simple scan set-up adjustment and imaging parameter optimization, which would allow for more streamlined and efficient UHF cardiac MRI.

Indexed as

Cardiac functionCineHigh-fieldMagnetic resonance imagingStrainTagging

Identifiers

PMID33240463
PMCPMC7653183