Repeatability of OCT-Based versus Scheimpflug- and Reflection-Based Keratometry in Patients with Hyperosmolar and Normal Tear Film.

Bjørn Gjerdrum, Kjell Gunnar Gundersen, Per Olof Lundmark, Bente Monica Aakre

Open access · goldAbstract read
In one paragraph

Article in Clinical ophthalmology (Auckland, N.Z.), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 17 papers.

0numbers the graph read from it
0cells of the map it votes in
17citing papers in PubMed
2.5field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

17 citing papers in PubMed, 23 citations in OpenAlex.

  1. Trial
  2. Trial
  3. Review
  4. Article
  5. Article
  6. Article
  7. Observational
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Current Developments in Corneal Topography and Tomography.Diagnostics (Basel, Switzerland) · 2021
    Review
  14. Article
  15. Article
  16. Article
  17. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Bjørn GjerdrumDepartment of Optometry, Radiography and Lighting Design, University of South-Eastern Norway, Kongsberg, Norway.ORCID 0000-0002-6886-5196
Kjell Gunnar GundersenIfocus Eye Clinic, Haugesund, Norway.ORCID 0000-0002-1003-0225
Per Olof LundmarkDepartment of Optometry, Radiography and Lighting Design, University of South-Eastern Norway, Kongsberg, Norway.ORCID 0000-0001-8293-6184
Bente Monica AakreDepartment of Optometry, Radiography and Lighting Design, University of South-Eastern Norway, Kongsberg, Norway.
University of South-Eastern Norway · NOPrivatsykehuset Haugesund · NO

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo compare the repeatability of keratometry between different instruments in patients with hyperosmolar tear film and a control group. PATIENTS AND

methodsSubjects with tear-film osmolarity of 316 mOsm/L or more in either eye or 308 m/Osm/L or lower in both eyes were assigned to the hyperosmolar and the control group, respectively. The test eye was the eye with higher osmolarity in the hyperosmolar group and randomly chosen in the control group. The repeatability of keratometry was compared between a reflectometry device (Haag-Streit Lenstar 900), a Scheimpflug device (Oculus Pentacam HR) and two optical coherence tomography (OCT) devices (Tomey Casia SS-1000 and Heidelberg Anterion), based on two measurements from each device.

resultsThe study included 94 subjects (31 hyperosmolar and 63 controls). Both OCT devices had higher mean differences of average simulated keratometry (SimK) vs the Lenstar in both groups, though all differences in means were <0.07 D. The Casia had the highest mean vector difference of SimK astigmatism in the control group (differences in means <0.11 D). These differences of the instruments were statistically significant (

conclusionBoth OCT devices show more variability in average SimK and the Casia more variability in SimK astigmatism compared to the Lenstar and the Pentacam. However, the results suggested that repeatability was not influenced by osmolarity.

Indexed as

hyperosmolarityOCTPlacido ringsreflectometryrepeatabilityScheimpflug

Identifiers

PMID33239862
PMCPMC7680682
OpenAlexW3098749940

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.