ArticleBMC pulmonary medicine2020
Serum heme oxygenase-1 measurement is useful for evaluating disease activity and outcomes in patients with acute respiratory distress syndrome and acute exacerbation of interstitial lung disease.
Article in BMC pulmonary medicine, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed, 16 citations in OpenAlex.
- Heme Oxygenase-1 as a Predictor of Early Allograft Dysfunction in Liver Transplantation: A Prospective Observational Pilot Study.Transplantation direct · 2026Article
- Heme oxygenase-1 and malaria pathogenesis.Frontiers in immunology · 2026Review
- Elevated serum heme oxygenase-1 in pediatric sickle cell disease: Insights from the SickleGenAfrica Network.HemaSphere · 2025Article
- Heme-induced lung injury in human precision cut lung slices: a new model for acute lung injury.Respiratory research · 2025Article
- Oxidative stress in ARDS: mechanisms and therapeutic potential.Frontiers in pharmacology · 2025Review
- Antioxidant and oxidative enzymes, genetic variants, and cofactors as prognostic biomarkers of COVID-19 severity and mortality: a systematic review.Frontiers in molecular biosciences · 2025Review
- Metabolic Regulation in Acute Respiratory Distress Syndrome: Implications for Inflammation and Oxidative Stress.International journal of chronic obstructive pulmonary disease · 2025Review
- Prognostic role of early blood gas variables in critically ill patients with Pneumocystis jirovecii pneumonia: a retrospective analysis.Critical care (London, England) · 2024Article
- Assessment of diagnostic utility of serum hemeoxygenase-1 measurement for acute exacerbation of interstitial pneumonias.Scientific reports · 2022Article
- Heme Oxygenase-1: An Anti-Inflammatory Effector in Cardiovascular, Lung, and Related Metabolic Disorders.Antioxidants (Basel, Switzerland) · 2022Review
- Article
- Clinical importance of serum heme oxygenase-1 measurement in patients with acute exacerbation of idiopathic pulmonary fibrosis triggered by coronavirus disease 2019.Respiratory medicine case reports · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors at 4 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundOxidative stress plays an important role in acute lung injury, which is associated with the development and progression of acute respiratory failure. Here, we investigated whether the degree of oxidative stress as indicated by serum heme oxygenase-1 (HO-1) is clinically useful for predicting prognosis among the patients with acute respiratory distress syndrome (ARDS) and acute exacerbation of interstitial lung disease (AE-ILD).
methodsSerum HO-1 levels of newly diagnosed or untreated ARDS and AE-ILD patients were measured at diagnosis. Relationships between serum HO-1 and other clinical parameters and 1 and 3-month mortality were evaluated.
resultsFifty-five patients including 22 of ARDS and 33 of AE-ILD were assessed. Serum HO-1 level at diagnosis was significantly higher in ARDS patients than AE-ILD patients (87.8 ± 60.0 ng/mL vs. 52.5 ± 36.3 ng/mL, P < 0.001). Serum HO-1 correlated with serum total bilirubin (R = 0.454, P < 0.001) and serum LDH (R = 0.500, P < 0.001). In both patients with ARDS and AE-ILDs, serum HO-1 level tended to decrease from diagnosis to 2 weeks after diagnosis, however, did not normalized. Composite parameters including serum HO-1, age, sex, and partial pressure of oxygen in arterial blood/fraction of inspired oxygen (P/F) ratio for prediction of 3-month mortality showed a higher AUC (ARDS: 0.925, AE-ILDs: 0.892) than did AUCs of a single predictor or combination of two or three predictors.
conclusionOxidative stress assessed by serum HO-1 is persistently high among enrolled patients for 2 weeks after diagnosis. Also, serum HO-1 levels at the diagnosis combined with age, sex, and P/F ratio could be clinically useful for predicting 3-month mortality in both ARDS and AE-ILD patients.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.