Evidence map›Paper›PMID 33236618›Full record

ArticleJournal of biomedical optics2020

Absolute retinal blood flowmeter using a laser Doppler velocimeter combined with adaptive optics.

Frederic Truffer, Martial Geiser, Marc-Antoine Chappelet, Helene Strese, Gilbert Maître, Serge Amoos, Florent Aptel, Christophe Chiquet

Open access · goldAbstract read
In one paragraph

Article in Journal of biomedical optics, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.4field-weighted citation impact, top 40% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 6 citations in OpenAlex.

  1. Review
  2. Article
  3. Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 2 countries.

Frederic TrufferUniversity of Applied Sciences and Arts of Western Switzerland, Institute of System Engineering, Sio, Switzerland.
Martial GeiserUniversity of Applied Sciences and Arts of Western Switzerland, Institute of System Engineering, Sio, Switzerland.
Marc-Antoine ChappeletUniversity Hospital, Department of Ophthalmology, Grenoble, France.
Helene StreseUniversity of Applied Sciences and Arts of Western Switzerland, Institute of System Engineering, Sio, Switzerland.
Gilbert MaîtreUniversity of Applied Sciences and Arts of Western Switzerland, Institute of System Engineering, Sio, Switzerland.
Serge AmoosUniversity of Applied Sciences and Arts of Western Switzerland, Institute of System Engineering, Sio, Switzerland.
Florent AptelUniversity Hospital, Department of Ophthalmology, Grenoble, France.
Christophe ChiquetUniversity Hospital, Department of Ophthalmology, Grenoble, France.
HES-SO University of Applied Sciences and Arts Western Switzerland · CHCentre Hospitalier Universitaire de Grenoble · FRUniversité Grenoble Alpes · FR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

significanceThe development of a technique allowing for non-invasive measurement of retinal blood flow (RBF) in humans is needed to understand many retinal vascular diseases (pathophysiology) and evaluate treatment with potential improvement of blood flow.

aimWe developed and validated an absolute laser Doppler velocimeter (LDV) based on an adaptive optical fundus camera that provides simultaneously high-definition images of the fundus vessels and absolute maximal red blood cells (RBCs) velocity to calculate the absolute RBF. APPROACH: This new absolute LDV is combined with the adaptive optics (AO) fundus camera (rtx1, Imagine Eyes©, Orsay, France) outside its optical wavefront correction path. A 4-s recording includes 40 images, each synchronized with two Doppler shift power spectra. Image analysis provides a vessel diameter close to the probing beam, and the velocity of the RBCs in the vessels are extracted from the Doppler spectral analysis. A combination of these values gives an average of the absolute RBF.

resultsAn in vitro experiment consisting of latex microspheres flowing in water through a glass capillary to simulate a blood vessel and in vivo measurements on six healthy humans was done to assess the device. In the in vitro experiment, the calculated flow varied between 1.75 and 25.9  μL  /  min and was highly correlated (r2  =  0.995) with the flow imposed by a syringe pump. In the in vivo experiment, the error between the flow in the parent vessel and the sum of the flow in the daughter vessels was between -11  %   and 36% (mean  ±  sd, 5.7  ±  18.5  %  ). RBF in the main temporal retinal veins of healthy subjects varied between 0.9 and 13.2  μL  /  min.

conclusionsThe AO LDV prototype allows for the real-time measurement of absolute RBF derived from the retinal vessel diameter and the maximum RBCs velocity in that vessel.

Indexed as

FlowmetersBlood Flow VelocityFluorescein AngiographyHumansLaser-Doppler FlowmetryLasersRegional Blood FlowRetinal Vesselsabsolute retinal blood flowfundus cameralaser Doppler velocimetryretinal blood flow

Identifiers

PMID33236618
PMCPMC7685387
OpenAlexW3106687334

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.