ArticleActa Cardiologica Sinica2020

Efficacy and Biosafety of a New Bioresorbable Vascular Scaffold Covered with Biodegradable Film in Rabbits: An In Vivo Study.

Wei Cai, En Chen, Xiaoling Zeng, Canqiang Chen, Lingzhen Wu, Xingchun Zheng, Lianglong Chen

Open access · greenAbstract read
In one paragraph

Article in Acta Cardiologica Sinica, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.4field-weighted citation impact, top 32% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 2 countries.

Wei CaiDepartment of Cardiology, Fujian Medical University Union Hospital, Provincial Institute of Coronary Artery Disease, Fujian, PR of China.
En ChenDepartment of Cardiology, Fujian Medical University Union Hospital, Provincial Institute of Coronary Artery Disease, Fujian, PR of China.
Xiaoling ZengDepartment of Cardiology, Fujian Medical University Union Hospital, Provincial Institute of Coronary Artery Disease, Fujian, PR of China.
Canqiang ChenDepartment of Cardiology, Fujian Medical University Union Hospital, Provincial Institute of Coronary Artery Disease, Fujian, PR of China.
Lingzhen WuDepartment of Cardiology, Fujian Medical University Union Hospital, Provincial Institute of Coronary Artery Disease, Fujian, PR of China.
Xingchun ZhengDepartment of Cardiology, Fujian Medical University Union Hospital, Provincial Institute of Coronary Artery Disease, Fujian, PR of China.
Lianglong ChenDepartment of Cardiology, Fujian Medical University Union Hospital, Provincial Institute of Coronary Artery Disease, Fujian, PR of China.
Fujian Medical University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundWe developed a new fully bioresorbable vascular scaffold covered with biodegradable poly-L-lactic acid film (Firesorb-C) for coronary artery perforation. Our vitro tests have demonstrated that Firesorb-C was technically feasible but its biosafety and efficacy warranted further validation in vivo.

objectiveThe aim of this study was to evaluate the biosafety and efficacy of Firesorb-C in rabbits.

methodsFiresorb-C was deployed at the zone from the abdominal aorta to the right iliac artery in five rabbits. Angiography was conducted for evaluation of the immediate efficacy and 6-month biosafety and biodegradability of the Firesorb-C. Meanwhile, optical coherence tomography (OCT), histological light microscopy (HLM) and scan electron microscopy (SEM) were performed to evaluate the biosafety.

resultsAll Firesorb-C applications were successfully implanted without procedure-related complications. In all treated rabbits, angiography showed that the Firesorb-C had completely sealed the opening of the left iliac artery without blood flow in its branches but with full patency of the right iliac artery immediately post-procedurally, while the covered membrane of Firesorb-C had been degraded and blood flow was restored in the left iliac artery and its branches at 6 months. OCT also found that the occluded left iliac artery had been reopened and the stented segment was almost fully endothelialized without in-stent restenosis at 6 months, meanwhile HLM and SEM confirmed comparable results.

conclusionsFiresorb-C is associated with excellent efficacy, biosafety and biodegradability in rabbits. It shows promise as a replacement for conventional covered stents for treatment of coronary artery perforation or for use in other clinical situations.

Indexed as

Biodegradable covered scaffoldCoronary artery perforationPoly-L-lactic-acidRabbit