Evidence map›Paper›PMID 33226709›Full record

ArticleJournal of applied clinical medical physics2020

Evaluation of cine imaging during multileaf collimator and gantry motion for real-time magnetic resonance guided radiation therapy.

Jerrold E Kielbasa, Sanford L Meeks, Patrick Kelly, Twyla R Willoughby, Omar Zeidan, Amish P Shah

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Jerrold E KielbasaDepartment of Radiation Oncology, Orlando Health - UF Health Cancer Center, Orlando, FL, USA.ORCID https://orcid.org/0000-0002-2854-9455
Sanford L MeeksDepartment of Radiation Oncology, Orlando Health - UF Health Cancer Center, Orlando, FL, USA.
Patrick KellyDepartment of Radiation Oncology, Orlando Health - UF Health Cancer Center, Orlando, FL, USA.
Twyla R WilloughbyDepartment of Radiation Oncology, Orlando Health - UF Health Cancer Center, Orlando, FL, USA.ORCID https://orcid.org/0000-0001-7665-5917
Omar ZeidanDepartment of Radiation Oncology, Orlando Health - UF Health Cancer Center, Orlando, FL, USA.
Amish P ShahDepartment of Radiation Oncology, Orlando Health - UF Health Cancer Center, Orlando, FL, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeReal-time magnetic resonance guided radiation therapy (MRgRT) uses 2D cine imaging for target tracking. This work evaluates the percent image uniformity (PIU) and spatial integrity of cine images in the presence of multileaf collimator (MLC) and gantry motion in order to simulate sliding window and volumetric modulated arc therapy (VMAT) conditions.

methodsPercent image uniformity and spatial integrity of cine images were measured (1) during MLC motion, (2) as a function of static gantry position, and (3) during gantry rotation. PIU was calculated according to the ACR MRI Quality Control Manual. Spatial integrity was evaluated by measuring the geometric distortion of 16 measured marker positions (10 cm or 15.225 cm from isocenter).

resultsThe PIU of cine images did not vary by more than 1% from static linac conditions during MLC motion and did not vary by more than 3% during gantry rotation. Banding artifacts were present during gantry rotation. The geometric distortion in the cine images was less than 0.88 mm for all points measured throughout MLC motion. For all static gantry positions, the geometric distortion was less than 0.88 mm at 10 cm from isocenter and less than 1.4 mm at 15.225 cm from isocenter. During gantry rotation, the geometric distortion remained less than 0.92 mm at 10 cm from isocenter and less than 1.60 mm at 15.225 cm from isocenter.

conclusionDuring MLC motion, cine images maintained adequate PIU, and the geometric distortion of points within 15.225 cm from isocenter was less than the 1 mm threshold necessary for real-time target tracking and gating. During gantry rotation, PIU was negatively affected by banding artifacts, and spatial integrity was only maintained within 10 cm from isocenter. Future work should investigate the effects imaging artifacts have on real-time target tracking during MRgRT.

Indexed as

Particle AcceleratorsRadiotherapy, Intensity-ModulatedHumansMagnetic Resonance ImagingMagnetic Resonance SpectroscopyQuality Controlcine MRIMRgRTpercent image uniformityspatial distortion

Identifiers

PMID33226709
PMCPMC7769407

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.