Trial reportStrahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al]2021
Pretreatment central quality control for craniospinal irradiation in non-metastatic medulloblastoma : First experiences of the German radiotherapy quality control panel in the SIOP PNET5 MB trial.
Trial report in Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al], 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed, 1 synthesis or guideline pooled it, 19 citations in OpenAlex.
- Questions and answers in the management of children with medulloblastoma over the time. How did we get here? A systematic review.Frontiers in oncology · 2023Pooled it
- A review of clinical trial radiotherapy quality assurance: value, evolution and lessons.Clinical and translational radiation oncology · 2026Review
- A feasibility study of functional preservation in craniospinal irradiation with photon for pediatric medulloblastoma.Journal of applied clinical medical physics · 2026Article
- Risk-adapted therapy in pediatric thyroid cancer: initial experience from a national reference program by the MET group.European thyroid journal · 2025Article
- Resection cavity auto-contouring for patients with pediatric medulloblastoma using only CT information.Journal of applied clinical medical physics · 2023Article
- Types of deviation and review criteria in pretreatment central quality control of tumor bed boost in medulloblastoma-an analysis of the German Radiotherapy Quality Control Panel in the SIOP PNET5 MB trial.Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] · 2022Article
- Local and Systemic Therapy of Recurrent Medulloblastomas in Children and Adolescents: Results of the P-HIT-REZ 2005 Study.Cancers · 2022Article
- Review
- Radiotherapy in Medulloblastoma-Evolution of Treatment, Current Concepts and Future Perspectives.Cancers · 2021Review
- Development of Randomized Trials in Adults with Medulloblastoma-The Example of EORTC 1634-BTG/NOA-23.Cancers · 2021Review
- Radiotherapy and COVID-19-everything under control or just the start of a long story?Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] · 2020Article
- An Analysis of Major Target Deviations in Craniospinal Irradiation Treatment Plans for Patients With Intermediate-Risk Medulloblastoma Within a Phase 3 Clinical Trial (Children's Oncology Group Study ACNS0331).Advances in radiation oncologyArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
24 authors at 15 institutions in 3 countries.
Funding
Abstract
purposeSeveral studies have demonstrated the negative impact of radiotherapy protocol deviations on tumor control in medulloblastoma. In the SIOP PNET5 MB trial, a pretreatment radiotherapy quality control (RT-QC) program was introduced. A first analysis for patients enrolled in Germany, Switzerland and Austria with focus on types of deviations in the initial plan proposals and review criteria for modern radiation technologies was performed. METHODS AND PATIENTS: Sixty-nine craniospinal irradiation (CSI) plans were available for detailed analyses. RT-QC was performed according to protocol definitions on dose uniformity. Because of the lack of definitions for high-precision 3D conformal radiotherapy within the protocol, additional criteria for RT-QC on delineation and coverage of clinical target volume (CTV) and planning target volume (PTV) were defined and evaluated.
resultsTarget volume (CTV/PTV) deviations occurred in 49.3% of initial CSI plan proposals (33.3% minor, 15.9% major). Dose uniformity deviations were less frequent (43.5%). Modification of the RT plan was recommended in 43.5% of CSI plans. Unacceptable RT plans were predominantly related to incorrect target delineation rather than dose uniformity. Unacceptable plans were negatively correlated to the number of enrolled patients per institution with a cutoff of 5 patients (p = 0.001).
conclusionThis prospective pretreatment individual case review study revealed a high rate of deviations and emphasizes the strong need of pretreatment RT-QC in clinical trials for medulloblastoma. Furthermore, the experiences point out the necessity of new RT-QC criteria for high-precision CSI techniques.