ArticleJournal of applied clinical medical physics2020
Effect of dental metal artifact conversion volume on dose distribution in head-and-neck volumetric-modulated arc therapy.
Article in Journal of applied clinical medical physics, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Deep learning-based metal artifact reduction in CT for head and neck radiotherapy.Physics and imaging in radiation oncology · 2026Review
- Correlation Between Dosimetric Parameters and Local Control in Definitive Radiotherapy for Head and Neck Cancers.In vivo (Athens, Greece)Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeDuring treatment planning for head-and-neck volumetric-modulated arc therapy (VMAT), manual contouring of the metal artifact area of artificial teeth is done, and the area is replaced with water computed tomography (CT) values for dose calculation. This contouring of the metal artifact areas, which is performed manually, is subject to human variability. The purpose of this study is to evaluate and analyze the effect of inter-observer variation on dose distribution.
methodsThe subjects were 25 cases of cancer of the oropharynx for which VMAT was performed. Six radiation oncologists (ROs) performed metal artifact contouring for all of the cases. Gross tumor volume, clinical target volume, planning target volume (PTV), and oral cavity were evaluated. The contouring of the six ROs was divided into two groups, small and large groups. A reference RO was determined for each group and the dose distribution was compared with those of the other radiation oncologists by gamma analysis (GA). As an additional experiment, we changed the contouring of each dental metal artifact area, creating enlarged contours (L), reduced contours (S), and undrawn contours (N) based on the contouring by the six ROs and compared these structure sets.
resultsThe evaluation of inter-observer variation showed no significant difference between the large and small groups, and the GA pass rate was 100%. Similar results were obtained comparing structure sets L and S, but in the comparison of structure sets L and N, there were cases with pass rates below 70%.
conclusionsThe results show that the artificial variability of manual artificial tooth metal artifact contouring has little effect on the dose distribution of VMAT. However, it should be noted that the dose distribution may change depending on the contouring method in cases where the overlap between PTV and metal artifact areas is large.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.