Validation of the Kinetik Blood Pressure Monitor-Series 1 for use in adults at home and in clinical settings, according to the 2002 European Society of Hypertension International Protocol on the validation of blood pressure devices.
Article in Journal of human hypertension, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Clinical validation of a wearable ultrasound sensor of blood pressure.Nature biomedical engineering · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
12 authors.
Funding
Abstract
The aim of this study was to assess the blood pressure (BP) measurement accuracy of the Kinetik Blood Pressure Monitor-Series 1 (BPM-1) for use in home or clinical settings according to the 2002 European Society of Hypertension International Protocol (ESH-IP). Forty-two participants were recruited to fulfil the required number of systolic and diastolic BP measurements according to the ESH-IP. Nine sequential same-arm BP readings were measured and analysed for each participant using the test device and observer mercury standard readings according to the 2002 ESH-IP. Forty one participants were used to obtain 33 sets of systolic and diastolic BP readings and were included in the analysis. Mean difference between the device measurements and the observer (mercury standard) measurements was 1.1 ± 7.2/1.1 ± 6.8 mmHg (mean ± standard deviation; systolic/diastolic). The number of systolic BP differences between the test and observer measurements that fell within 5, 10 and 15 mmHg was 65, 86 and 92. For diastolic readings, the number of test-observer measurement differences within 5, 10 and 15 mmHg was 77, 91 and 94. The number of participants with at least two out of three differences within 5 mmHg was 28 for systolic and 40 for diastolic BP readings. Three participants had no differences between the test and observer measurements within 5 mmHg in both the systolic and diastolic measurement categories. The Kinetik BPM-1 device fulfilled the requirements of the ESH-IP validation procedure and can be recommended for clinical use and self-measurement within the home.