ArticleBMC musculoskeletal disorders2020
Double plating with autogenous bone grafting as a salvage procedure for recalcitrant humeral shaft nonunion.
Article in BMC musculoskeletal disorders, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed.
- Intercalary tumor prosthesis for recalcitrant humeral shaft nonunions: a case series and technique.JSES reviews, reports, and techniques · 2026Article
- Twenty-year Delayed Failure of an Intramedullary Humeral Nail Due to Shaft Non-union and its Surgical Management: A Case Report.Journal of orthopaedic case reports · 2026Article
- Rare "double tragedy" and successful salvage strategy after failed bilateral humeral fracture fixation in a resource-constrained setting: a case report.Patient safety in surgery · 2025Article
- Treatment of infected humeral shaft nonunion and presumed aseptic nonunion with positive intraoperative cultures: a retrospective single-center study.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2024Article
- Review
- Infected humeral shaft nonunion treatment with the induced membrane technique and a novel fixation construct: a case report.OTA international : the open access journal of orthopaedic trauma · 2024Article
- Consistent Protocol-Based Management of Humerus Shaft Nonunion: An Analysis of 100 Cases.Indian journal of orthopaedics · 2023Article
- A novel bone graft technique combined with plating for aseptic recalcitrant long bone nonunion.BMC musculoskeletal disorders · 2022Article
- A Composite Deferoxamine/Black Phosphorus Nanosheet/Gelatin Hydrogel Scaffold for Ischemic Tibial Bone Repair.International journal of nanomedicine · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundAlthough most cases of humeral shaft nonunion respond well to surgical intervention, surgeons still encounter patients with humeral shaft nonunion who have already undergone repeated surgeries for nonunion. This study retrospectively analyzed the efficacy of double locking compression plate (LCP) fixation in combination with autogenous iliac crest bone grafting for recalcitrant humeral shaft nonunion.
methodsA consecutive series of patients with aseptic recalcitrant humeral shaft nonunion underwent surgical treatment between May 2010 and August 2017 in our institution. Standardized treatment included thorough debridement, double LCP and screw fixation, and autogenous iliac bone grafting. The injury type and the duration of nonunion were recorded for all patients. The main outcome measurements were the Constant and Murley scale for shoulder function, Mayo elbow performance index (MEPI) for elbow function, and visual analog scale (VAS) for pain. In addition, all complications were documented.
resultsThe study cohort comprised six females and nine males with a mean age of 45.3 ± 13.1 years. Each patient had already undergone at least one failed surgery for humeral shaft nonunion. The average duration of nonunion before the index intervention was 126.8 ± 124.2 months. All patients achieved bone union without implant failure. At final follow-up, the mean Constant and Murley score and mean MEPI were significantly improved, and the mean VAS score was significantly decreased. Each patient was very satisfied with the treatment. Four patients had complications, including one with a superficial wound infection, one with radial nerve palsy, one with ulnar nerve palsy, and one with discomfort at the iliac crest.
conclusionDouble plate fixation combined with autogenous iliac crest bone grafting results in successful salvage of humeral shaft nonunion after prior failed surgical interventions.