Evidence map›Paper›PMID 33219728›Full record

ArticlePediatric diabetes2021

Performance of three different continuous glucose monitoring systems in children with type 1 diabetes during a diabetes summer camp.

Katrin Nagl, Gabriele Berger, Felix Aberer, Haris Ziko, Katharina Weimann, Ina Bozic, Birgit Rami-Merhar, Julia K Mader

Open access · bronzeAbstract readComparative Study
In one paragraph

Article in Pediatric diabetes, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
1.6field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 20 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Katrin NaglDepartment of Pediatrics and Adolescent Medicine, Medical University Vienna, Austria.ORCID 0000-0001-6489-9068
Gabriele BergerDepartment of Pediatrics and Adolescent Medicine, Medical University Vienna, Austria.ORCID 0000-0002-5706-5839
Felix AbererDivision of Endocrinology and Diabetology, Department of Internal Medicine, Medical University of Graz, Austria.ORCID 0000-0002-9947-1413
Haris ZikoDivision of Endocrinology and Diabetology, Department of Internal Medicine, Medical University of Graz, Austria.
Katharina WeimannDepartment of Pediatrics and Adolescent Medicine, Medical University Vienna, Austria.
Ina BozicDepartment of Pediatrics and Adolescent Medicine, Medical University Vienna, Austria.
Birgit Rami-MerharDepartment of Pediatrics and Adolescent Medicine, Medical University Vienna, Austria.ORCID 0000-0001-5575-5222
Julia K MaderDivision of Endocrinology and Diabetology, Department of Internal Medicine, Medical University of Graz, Austria.ORCID 0000-0001-7854-4233
Medical University of Vienna · ATMedical University of Graz · AT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The aim of this study was to assess accuracy of the three most commonly used continuous glucose monitoring (CGM) systems in almost real-life situation during a diabetes camp in children with type 1 diabetes (T1D) aged 9-14 years. Data was gathered during a 2-week summer camp under physicians' supervision. Out of 38 participating children with T1D (aged: 11.0 [9.9; 12.1] years; 57% girls, mean HbA1c 7.2 [6.9; 7.7] %,) 37 wore a CGM system (either Abbott FreeStyle Libre (FSL), Dexcom G6 (DEX) or Medtronic Enlite (ENL)) throughout the camp. All concomitantly available data pairs of capillary glucose measurements and sensor values were used for the analysis. Mean absolute relative difference (MARD) was calculated and Parkes Error Grid analyses were done for all three systems used. In total 2079 data pairs were available for analysis. The overall MARDs of CGM systems used at the camp was FSL: 13.3% (6.7;21.6). DEX: 10.3% (5.8; 16.7) and ENL 8.5% (3.6; 15.6). During eu-, hypo- and hyperglycemia MARDs were lowest in ENL. Highest MARDs were seen in hypoglycemia, where all three systems exhibited MARDs above 15%. Overnight MARDs of all systems was higher than during daytime. All sensors performed worst in hypoglycemia. Performance of the adequately calibrated Medtronic system outperformed the factory-calibrated sensors. For clinical practice, it is important to adequately train children with T1D and families in the correct procedures for sensors that require calibrations.

Indexed as

CampingAdolescentBlood GlucoseBlood Glucose Self-MonitoringChildDiabetes Mellitus, Type 1FemaleGlycated HemoglobinHumansMaleReproducibility of ResultsBlood GlucoseGlycated HemoglobinaccuracycalibrationCGMchildrensensortype 1 diabetes

Identifiers

PMID33219728
PMCPMC7984061
OpenAlexW3100546719

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.