Evidence map›Paper›PMID 33217896›Full record

ArticleSensors (Basel, Switzerland)2020

Remote Pain Monitoring Using Fog Computing for e-Healthcare: An Efficient Architecture.

Syed Rizwan Hassan, Ishtiaq Ahmad, Shafiq Ahmad, Abdullah Alfaify, Muhammad Shafiq

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Syed Rizwan HassanDepartment of Electrical Engineering, The University of Lahore, Lahore 54000, Pakistan.ORCID 0000-0002-6206-3934
Ishtiaq AhmadDepartment of Electrical Engineering, The University of Lahore, Lahore 54000, Pakistan.
Shafiq AhmadIndustrial Engineering Department, College of Engineering, King Saud University, P.O. Box 800, Riyadh 11421, Saudi Arabia.ORCID 0000-0003-0712-9133
Abdullah AlfaifyIndustrial Engineering Department, College of Engineering, King Saud University, P.O. Box 800, Riyadh 11421, Saudi Arabia.ORCID 0000-0001-9386-1720
Muhammad ShafiqDepartment of Information and Communication Engineering, Yeungnam University, Gyeongsan 38541, Korea.ORCID 0000-0001-7337-7608

Funding

King Saud University, Riyadh, Saudi Arabia RSP-2020/256
6 · The paper itself

Abstract

The integration of medical signal processing capabilities and advanced sensors into Internet of Things (IoT) devices plays a key role in providing comfort and convenience to human lives. As the number of patients is increasing gradually, providing healthcare facilities to each patient, particularly to the patients located in remote regions, not only has become challenging but also results in several issues, such as: (i) increase in workload on paramedics, (ii) wastage of time, and (iii) accommodation of patients. Therefore, the design of smart healthcare systems has become an important area of research to overcome these above-mentioned issues. Several healthcare applications have been designed using wireless sensor networks (WSNs), cloud computing, and fog computing. Most of the e-healthcare applications are designed using the cloud computing paradigm. Cloud-based architecture introduces high latency while processing huge amounts of data, thus restricting the large-scale implementation of latency-sensitive e-healthcare applications. Fog computing architecture offers processing and storage resources near to the edge of the network, thus, designing e-healthcare applications using the fog computing paradigm is of interest to meet the low latency requirement of such applications. Patients that are minors or are in intensive care units (ICUs) are unable to self-report their pain conditions. The remote healthcare monitoring applications deploy IoT devices with bio-sensors capable of sensing surface electromyogram (sEMG) and electrocardiogram (ECG) signals to monitor the pain condition of such patients. In this article, fog computing architecture is proposed for deploying a remote pain monitoring system. The key motivation for adopting the fog paradigm in our proposed approach is to reduce latency and network consumption. To validate the effectiveness of the proposed approach in minimizing delay and network utilization, simulations were carried out in iFogSim and the results were compared with the cloud-based systems. The results of the simulations carried out in this research indicate that a reduction in both latency and network consumption can be achieved by adopting the proposed approach for implementing a remote pain monitoring system.

Indexed as

Internet of ThingsRemote Sensing TechnologyTelemedicineCloud ComputingDelivery of Health CareElectrocardiographyElectromyographyHumansPainWireless Technologycloud computinge-healthcarefog computingIoTremote pain monitoring

Identifiers

PMID33217896
PMCPMC7698725

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.