Evidence map›Paper›PMID 33217535›Full record

ArticleIndian pacing and electrophysiology journal

Implantation of the Micra transcatheter pacing system: A single center North India experience.

Viveka Kumar, Rajendra Agarwal, Mitendra Singh Yadav, Sangeeta Dhir, Vivek Kumar

Erratum issuedAbstract read
In one paragraph

Article in Indian pacing and electrophysiology journal. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Materials Advances in Devices for Heart Disease Interventions.Advanced materials (Deerfield Beach, Fla.) · 2025
    Review
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

5 authors.

Viveka KumarDirector, Cath Labs, Department of Cardiology, Max Superspeciality Hospital, New Delhi, India. Electronic address: viveka.kumar@maxhealthcare.com.
Rajendra AgarwalDNB Interventional Cardiology, Department of Cardiology Max Superspeciality Hospital, New Delhi, India. Electronic address: rajendramax@hotmail.com.
Mitendra Singh YadavDepartment of Cardiology, Max Superspeciality Hospital, New Delhi, India. Electronic address: mitendra.s@gmail.com.
Sangeeta DhirMDS Periodontology, Fellow Implantology Department of Cardiology, Max Superspeciality Hospital, New Delhi, India. Electronic address: sangeeta_dhir@hotmail.com.
Vivek KumarDepartment of Cardiology, Max Superspeciality Hospital, New Delhi, India. Electronic address: drvivek@gmail.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe leadless pacemaking transcatheter system, Micra, is a miniaturized, single-chamber pacemaker system. We report herein our experience with implantation of the Micra TPS system.

objectiveThe current study was conducted to evaluate the safety and efficacy of the leadless Micra Transcatheter Pacemaker System (Medtronic). RESEARCH DESIGN AND

methodsThis was a prospective single centre nonrandomized study without controls. A transcatheter pacemaker was implanted in patients who had guideline based indications for ventricular pacing. 28 subjects were screened based on the selection criteria. Mica TPS was implanted. Parameters assessed were: duration of procedure (from femoral vein puncture to venous access closure), fluoroscopy time, number of device repositions, periprocedural electrical measurements (sensing, threshold and impedance) and in-hospital, intermediate to long term adverse events related to procedure. RESULT AND

conclusions: The device was successfully implanted in 28 subjects. The mean intraoperative sensing value was 9.04 ± 1.5 mV and the impedance was 766.89 ± 213.9 Ω. At discharge from hospital, those values were 13.2 ± 15.83 mV and 855 ± 111.7, respectively. The recommended pacing threshold value as achieved in all subjects was 0.78 V, i.e. ≤ 1 V at 0.24 ms. There was no adverse event or complications reported for any of the subjects. Mean time from hospitalization to discharge was 1.5 days. Implantation of leadless pacemakers is feasible, safe and provides advantages over the conventional system.

Indexed as

BradycardiaLeadless pacemakerLeadless pacing system, cardiac pacingMicra TPSMicra transcatheter pacing system

Identifiers

PMID33217535
PMCPMC7854371

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.