Evidence map›Paper›PMID 33215393›Full record

ArticleNeurocritical care2021

The Neurological Examination Improves Cranial Accelerometry Large Vessel Occlusion Prediction Accuracy.

Kevin J Keenan, Paul A Lovoi, Wade S Smith

Open access · greenAbstract read
In one paragraph

Article in Neurocritical care, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed, 1 pooled it
1.3field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 1 synthesis or guideline pooled it, 12 citations in OpenAlex.

  1. Pooled it
  2. Large vessel occlusion prediction scale thresholds that are sensitive for DAWN Trial patients.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2025
    Article
  3. Prehospital technologies for early stroke detection - A review.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2025
    Review
  4. Review
  5. Article
  6. Large Vessel Occlusion Stroke Detection in the Prehospital Environment.Current emergency and hospital medicine reports · 2021
    Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Kevin J KeenanDepartment of Neurology, University of California, Davis, 4860 Y Street, Suite 3700, Sacramento, CA, 95817, USA. kjkeenan@ucdavis.edu.ORCID http://orcid.org/0000-0002-5643-9878
Paul A LovoiDepartment of Neurology, University of California, San Francisco, San Francisco, CA, USA.
Wade S SmithDepartment of Neurology, University of California, San Francisco, San Francisco, CA, USA.
University of California, San Francisco · US

Funding

Smith_U24_Supplement P0570485 5 30 2023U24NS107229 · NINDS · UNIVERSITY OF CALIFORNIA, SAN FRANCISCO · PI Anthony Suyoung Kim · 2018 to 2026
$2.9M
NorCal - Coordinating Stroke CenterU10NS086494 · NINDS · UNIVERSITY OF CALIFORNIA, SAN FRANCISCO · PI SMITH, WADE S · 2013 to 2017
$2.0M
NINDS NIH HHS U10 NS086494NINDS NIH HHS U24 NS107229
6 · The paper itself

Abstract

BACKGROUND/

objectiveWe combined cranial accelerometry, a device-based approach to large vessel occlusion (LVO) prediction, with neurological examination findings to determine if this improves diagnostic accuracy compared to either alone.

methodsCranial accelerometry recordings and NIHSS scores were obtained during stroke codes and thrombectomy transfers at an academic medical center using convenience sampling. The reference standard was discharge diagnosis of LVO stroke. We compared accuracy statistics between machine learning models trained using cranial accelerometry alone, with asymmetric arm weakness added, with NIHSS scores added, and retrospective examination only LVO prediction scales. An exploratory analysis required asymmetric arm weakness prior to model training or scale testing.

resultsOf 68 patients, there were 23 LVO strokes. Cranial accelerometry was 65% sensitive (95% CI 43-84%) and 87% specific (95% CI 73-95%). Adding asymmetric arm weakness increased specificity to 91% (95% CI 79-98%). Adding asymmetric arm weakness and the NIHSS increased sensitivity to 74% (95% CI 52-90%) and decreased specificity to 89% (95% CI 76-96%). LVO prediction scales had wide sensitivity and specificity ranges. The exploratory analysis improved sensitivity to 91% (95% CI 72-99%) and specificity to 93% (95% CI 92-99%) with only three false positives and two false negatives.

conclusionsCranial accelerometry models are improved by various additions of asymmetric arm weakness and the NIHSS. An exploratory analysis requiring asymmetric arm weakness prior to cranial accelerometry model training minimized false positives and negatives.

Indexed as

Brain IschemiaStrokeAccelerometryHumansNeurologic ExaminationPredictive Value of TestsRetrospective StudiesArteriesComputed tomography angiographyDiagnostic techniqueIntracranial thrombosisMedical deviceNeurologicalStrokeThrombectomy

Identifiers

PMID33215393
PMCPMC12131181
OpenAlexW3103776949

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.