Evidence map›Paper›PMID 33215329›Full record

ArticleInternational journal of implant dentistry2020

Platelet adhesion on commercially pure titanium plates in vitro III: effects of calcium phosphate-blasting on titanium plate biocompatibility.

Masayuki Nakamura, Hachidai Aizawa, Hideo Kawabata, Atsushi Sato, Taisuke Watanabe, Kazushige Isobe, Yutaka Kitamura, Takaaki Tanaka, Tomoyuki Kawase

Open access · diamondAbstract read
In one paragraph

Article in International journal of implant dentistry, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.7field-weighted citation impact, top 29% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 2 institutions in 1 country.

Masayuki NakamuraTokyo Plastic Dental Society, Kita-ku, Tokyo, Japan.
Hachidai AizawaTokyo Plastic Dental Society, Kita-ku, Tokyo, Japan.
Hideo KawabataTokyo Plastic Dental Society, Kita-ku, Tokyo, Japan.
Atsushi SatoTokyo Plastic Dental Society, Kita-ku, Tokyo, Japan.
Taisuke WatanabeTokyo Plastic Dental Society, Kita-ku, Tokyo, Japan.
Kazushige IsobeTokyo Plastic Dental Society, Kita-ku, Tokyo, Japan.
Yutaka KitamuraTokyo Plastic Dental Society, Kita-ku, Tokyo, Japan.
Takaaki TanakaDepartment of Materials Science and Technology, Niigata University, Niigata, Japan.
Tomoyuki KawaseDivision of Oral Bioengineering, Institute of Medicine and Dentistry, Niigata University, Niigata, Japan. kawase@dent.niigata-u.ac.jp.ORCID http://orcid.org/0000-0003-4160-396X
Tokyo Dental College · JPNiigata University · JP

Funding

Japan Society for the Promotion of Science 18K09595
6 · The paper itself

Abstract

backgroundPlatelet-rich plasma (PRP) is often used to improve surface biocompatibility. We previously found that platelets rapidly adhere to plain commercially pure titanium (cp-Ti) plates in the absence, but not in the presence, of plasma proteins. To further expand on these findings, in the present study, we switched titanium plates from a plain surface to a rough surface that is blasted with calcium phosphate (CaP) powder and then examined platelet adhesion and activation.

methodsElemental distribution in CaP-blasted cp-Ti plates was analyzed using energy-dispersive X-ray spectroscopy. PRP samples prepared from anticoagulated blood samples of six healthy, non-smoking adult male donors were loaded on CaP-blasted cp-Ti plates for 1 h and fixed for examination of platelet morphology and visualization of PDGF-B and platelet surface markers (CD62P, CD63) using scanning electron microscopy and fluorescence microscopy. Plain SUS316L stainless steel plates used in injection needles were also examined for comparison.

resultsSignificant amounts of calcium and phosphate were detected on the CaP-blasted cp-Ti surface. Platelets rapidly adhered to this surface, leading to higher activation. Platelets also adhered to the plain stainless surface; however, the levels of adhesion and activation were much lower than those observed on the CaP-blasted cp-Ti plate.

conclusionsThe CaP-blasted cp-Ti surface efficiently entraps and activates platelets. Biomolecules released from the activated platelets could be retained by the fibrin matrix on the surface to facilitate regeneration of the surrounding tissues. Thus, PRP immersion could not only eliminate surface air bubbles but also improve the biocompatibility of the implant surface.

Indexed as

BlastingCalcium phosphatesCD62PCD63ImplantPlatelet-rich plasmaTitanium

Identifiers

PMID33215329
PMCPMC7677422
OpenAlexW3106389126

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.