Evaluation of an Element-Tagged Duplex Immunoassay Coupled with Inductively Coupled Plasma Mass Spectrometry Detection: A Further Study for the Application of the New Assay in Clinical Laboratory.

Wencan Jiang, Gongwei Sun, Wenbin Cui, Shasha Men, Miao Jing, Danna Pu, Sichun Zhang, Xiaozhou Yuan, Xinrong Zhang, Chengbin Wang

Open access · goldAbstract read
In one paragraph

Article in Molecules (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.6field-weighted citation impact, top 34% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 12 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 4 institutions in 1 country.

Wencan JiangDepartment of Clinical Laboratory Medicine, Chinese People's Liberation Army General Hospital & Postgraduate Medical School, Beijing 100853, China.
Gongwei SunBeijing Key Laboratory for Microanalytical Methods and Instrumentation, Department of Chemistry, Tsinghua University, Beijing 100084, China.
Wenbin CuiChromatography & Mass Spectrometry Thermo Fisher Scientific, China Commercial, Beijing 100853, China.
Shasha MenDepartment of Clinical Laboratory Medicine, Chinese People's Liberation Army General Hospital & Postgraduate Medical School, Beijing 100853, China.
Miao JingChromatography & Mass Spectrometry Thermo Fisher Scientific, China Commercial, Beijing 100853, China.
Danna PuDepartment of Clinical Laboratory Medicine, Chinese People's Liberation Army General Hospital & Postgraduate Medical School, Beijing 100853, China.
Sichun ZhangBeijing Key Laboratory for Microanalytical Methods and Instrumentation, Department of Chemistry, Tsinghua University, Beijing 100084, China.
Xiaozhou YuanDepartment of Clinical Laboratory Medicine, Chinese People's Liberation Army General Hospital & Postgraduate Medical School, Beijing 100853, China.
Xinrong ZhangBeijing Key Laboratory for Microanalytical Methods and Instrumentation, Department of Chemistry, Tsinghua University, Beijing 100084, China.
Chengbin WangDepartment of Clinical Laboratory Medicine, Chinese People's Liberation Army General Hospital & Postgraduate Medical School, Beijing 100853, China.
People's Liberation Army No. 150 Hospital · CNTsinghua University · CNChinese People's Liberation Army · CNThermo Fisher Scientific (China) · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundElement-tagged immunoassay coupled with inductively coupled plasma mass spectrometry (ICP-MS) detection has the potential to revolutionize immunoassay analysis for multiplex detection. However, a further study referring to the standard evaluation and clinical sample verification is needed to ensure its reliability for simultaneous analysis in clinical laboratories.

methodsCarcinoembryonic antigen (CEA) and α-fetoprotein (AFP) were chosen for the duplex immunoassay. The performance of the assay was evaluated according to guidelines from the Clinical and Laboratory Standards Institute (CLSI). Moreover, reference intervals (RIs) of CEA and AFP were established. At last, 329 clinical samples were analyzed by the proposed method and results were compared with those obtained with electrochemiluminescent immunoassay (ECLIA) method.

resultsThe measurement range of the assay was 2-940 ng/mL for CEA and 1.5-1000 ng/mL for AFP, with a detection limit of 0.94 ng/mL and 0.34 ng/mL, respectively. The inter-assay and intra-assay imprecision were all less than 6.58% and 10.62%, respectively. The RI of CEA and AFP was 0-3.84 ng/mL and 0-9.94 ng/mL, respectively. Regarding to clinical sample detection, no significant difference was observed between the proposed duplex assay and the ECLIA method.

conclusionsThe ICP-MS-based duplex immunoassay was successfully developed and the analytical performance fully proved clinical applicability. Well, this could be different with other analytes.

Indexed as

ElementsMass SpectrometryAdultAgedalpha-FetoproteinsCalibrationCarcinoembryonic AntigenClinical Laboratory TechniquesFemaleGPI-Linked ProteinsHumansImmunoassayLuminescent MeasurementsMaleMiddle AgedReference Valuesalpha-FetoproteinsCarcinoembryonic AntigenCEACAM5 protein, humanElementsGPI-Linked ProteinsAFPCEAclinical sample detectionevaluationICP-MS-based duplex immunoassayperformance

Identifiers

PMID33212898
PMCPMC7698432
OpenAlexW3105814182

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.