Evidence map›Paper›PMID 33211692›Full record

Observational studyPloS one2020

Early results of a low-profile stent-graft for thoracic endovascular aortic repair.

Hazem El Beyrouti, Mario Lescan, Marco Doemland, Migdat Mustafi, Florian Jungmann, Tobias Jorg, Nancy Halloum, Bernhard Dorweiler

Open access · goldAbstract readMulticenter StudyObservational Study
In one paragraph

Observational study in PloS one, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
0.6field-weighted citation impact, top 26% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 11 citations in OpenAlex.

  1. Article
  2. Late Outcomes of Thoracic Endovascular Aneurysm Repair Outside Versus Inside Instruction for Use.European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery · 2025
    Article
  3. Article
  4. Article
  5. Article
  6. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Hazem El BeyroutiDepartment of Cardiothoracic and Vascular Surgery, University Medical Center of the Johannes Gutenberg University Mainz, Mainz, Germany.ORCID 0000-0001-6070-9490
Mario LescanDepartment of Thoracic and Cardiovascular Surgery, University Medical Center Tübingen, Tübingen, Germany.
Marco DoemlandDepartment of Cardiothoracic and Vascular Surgery, University Medical Center of the Johannes Gutenberg University Mainz, Mainz, Germany.
Migdat MustafiDepartment of Thoracic and Cardiovascular Surgery, University Medical Center Tübingen, Tübingen, Germany.
Florian JungmannDepartment of Diagnostic and Interventional Radiology, University Medical Center of the Johannes Gutenberg University Mainz, Mainz, Germany.
Tobias JorgDepartment of Diagnostic and Interventional Radiology, University Medical Center of the Johannes Gutenberg University Mainz, Mainz, Germany.
Nancy HalloumDepartment of Cardiothoracic and Vascular Surgery, University Medical Center of the Johannes Gutenberg University Mainz, Mainz, Germany.
Bernhard DorweilerDepartment of Vascular Surgery, University Medical Center, Cologne, Germany.
Johannes Gutenberg University Mainz · DEUniversity of Tübingen · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo assess outcomes of a low-profile thoracic stent-graft in the treatment of thoracic aortic pathologies.

methodsA retrospective analysis of all consecutive patients with aortic thoracic pathologies treated with the RelayPro device in two university hospitals between October 2018 and July 2019.

results23 patients (65% men; mean age 63.4 ± 15 years) were treated. Pathologies included aortic dissections (n = 10), 5 residual type A (22%) and 5 type B (22%), 6 degenerative aortic aneurysms (26%), 4 penetrating aortic ulcers (17%), and aortic erosion, intramural hematoma and aortic rupture (n = 1 and 4% in each case). Two cases (9%) were emergent and two urgent. Proximal landing was achieved in zones 0 (4%), 1 (4%), 2 (43%), and 3 (26%). Five grafts were frozen elephant trunk extensions. Technical success was 100% with accurate device deployment in the intended landing zone of the aortic arch in all 23 patients and with no Ia/III endoleaks and three (13%) type II endoleaks. Apposition was adequate in 96%. Two patients had post-implantation syndromes (one fever, one leukocytosis). Mean follow-up was 11.6 ± 3.7 months (range, 2-16) with no other complications, secondary interventions or conversions to open surgery. There was no 30-day mortality and no aortic-related mortality; all-cause mortality was 4% during follow-up.

conclusionA 3-4 French reduced profile in the current generation of stent-grafts facilitates TEVAR particularly in patients with smaller vessels access. Early safety and effectiveness outcomes are favorable, even in endpoints such as deployment accuracy and apposition which may be surrogates for longer-term clinical success and durability.

Indexed as

AgedAged, 80 and overAorta, ThoracicAortic DiseasesBlood Vessel Prosthesis ImplantationEndoleakFemaleHumansMiddle AgedPostoperative ComplicationsRetrospective StudiesStentsTreatment Outcome

Identifiers

PMID33211692
PMCPMC7676711
OpenAlexW3104475625

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.