Evidence map›Paper›PMID 33211319›Full record

SynthesisThe Cochrane database of systematic reviews2020

Routine laboratory testing to determine if a patient has COVID-19.

Inge Stegeman, Eleanor A Ochodo, Fatuma Guleid, Gea A Holtman, Bada Yang, Clare Davenport, Jonathan J Deeks, Jacqueline Dinnes, Sabine Dittrich, Devy Emperador and 9 more

Open access · bronzeAbstract readMeta-AnalysisSystematic Review
In one paragraph

Synthesis in The Cochrane database of systematic reviews, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 46 papers, 12 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
46citing papers in PubMed, 12 pooled it
1.7field-weighted citation impact, top 9% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

46 citing papers in PubMed, 12 syntheses or guidelines pooled it, 77 citations in OpenAlex.

  1. Rapid, point-of-care antigen tests for diagnosis of SARS-CoV-2 infection.The Cochrane database of systematic reviews · 2025
    Pooled it
  2. Pooled it
  3. Pooled it
  4. Pooled it
  5. Pooled it
  6. Rapid, point-of-care antigen tests for diagnosis of SARS-CoV-2 infection.The Cochrane database of systematic reviews · 2022
    Pooled it
  7. Pooled it
  8. Thoracic imaging tests for the diagnosis of COVID-19.The Cochrane database of systematic reviews · 2022
    Pooled it
  9. Pooled it
  10. Pooled it
  11. Thoracic imaging tests for the diagnosis of COVID-19.The Cochrane database of systematic reviews · 2021
    Pooled it
  12. Pooled it
  13. Trial
  14. Article
  15. Article
  16. Effectiveness of SARS-CoV-2 testing strategies.The Cochrane database of systematic reviews · 2025
    Article
  17. Article
  18. Review
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

19 authors at 11 institutions in 6 countries.

Inge StegemanDepartment of Otorhinolaryngology & Head and Neck Surgery, University Medical Center Utrecht, Utrecht, Netherlands.
Eleanor A OchodoCentre for Evidence-based Health Care, Department of Global Health, Faculty of Medicine and Health Sciences, Stellenbosch University, Cape Town, South Africa.
Fatuma GuleidKEMRI-Wellcome Trust Research Programme, Nairobi, Kenya.
Gea A HoltmanDepartment of General Practice, University of Groningen, University Medical Centre Groningen, Groningen, Netherlands.
Bada YangEpidemiology and Data Science, Amsterdam University Medical Centers, University of Amsterdam, Amsterdam, Netherlands.
Clare DavenportTest Evaluation Research Group, Institute of Applied Health Research, University of Birmingham, Birmingham, UK.
Jonathan J DeeksTest Evaluation Research Group, Institute of Applied Health Research, University of Birmingham, Birmingham, UK.
Jacqueline DinnesTest Evaluation Research Group, Institute of Applied Health Research, University of Birmingham, Birmingham, UK.
Sabine DittrichFIND, Geneva, Switzerland.
Devy EmperadorFIND, Geneva, Switzerland.
Lotty HooftCochrane Netherlands, Julius Center for Health Sciences and Primary Care, University Medical Center Utrecht, Utrecht University, Utrecht, Netherlands.
René SpijkerCochrane Netherlands, Julius Center for Health Sciences and Primary Care, University Medical Center Utrecht, Utrecht University, Utrecht, Netherlands.
Yemisi TakwoingiTest Evaluation Research Group, Institute of Applied Health Research, University of Birmingham, Birmingham, UK.
Ann Van den BruelDepartment of Public Health and Primary Care, KU Leuven, Leuven, Belgium.
Junfeng WangJulius Center for Health Sciences and Primary Care, University Medical Center Utrecht, Utrecht, Netherlands.
Miranda LangendamEpidemiology and Data Science, Amsterdam University Medical Centers, University of Amsterdam, Amsterdam, Netherlands.
Jan Y VerbakelDepartment of Public Health and Primary Care, KU Leuven, Leuven, Belgium.
Mariska Mg LeeflangEpidemiology and Data Science, Amsterdam University Medical Centers, University of Amsterdam, Amsterdam, Netherlands.
Cochrane COVID-19 Diagnostic Test Accuracy GroupNIHR Birmingham Biomedical Research Centre, University Hospitals Birmingham NHS Foundation Trust and University of Birmingham, Birmingham, UK.
Amsterdam University Medical Centers · NLFoundation for Innovative New Diagnostics · CHKU Leuven · BENIHR Birmingham Biomedical Research Centre · GBUniversity Medical Center Utrecht · NLKenya Medical Research Institute · KEStellenbosch University · ZAUniversity Hospitals Birmingham NHS Foundation Trust · GBUniversity of Birmingham · GBUniversity of Groningen · NLUtrecht University · NL

Funding

Medical Research Council MR/T008768/1
6 · The paper itself

Abstract

backgroundSpecific diagnostic tests to detect severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and resulting COVID-19 disease are not always available and take time to obtain results. Routine laboratory markers such as white blood cell count, measures of anticoagulation, C-reactive protein (CRP) and procalcitonin, are used to assess the clinical status of a patient. These laboratory tests may be useful for the triage of people with potential COVID-19 to prioritize them for different levels of treatment, especially in situations where time and resources are limited.

objectivesTo assess the diagnostic accuracy of routine laboratory testing as a triage test to determine if a person has COVID-19. SEARCH

methodsOn 4 May 2020 we undertook electronic searches in the Cochrane COVID-19 Study Register and the COVID-19 Living Evidence Database from the University of Bern, which is updated daily with published articles from PubMed and Embase and with preprints from medRxiv and bioRxiv. In addition, we checked repositories of COVID-19 publications. We did not apply any language restrictions. SELECTION CRITERIA: We included both case-control designs and consecutive series of patients that assessed the diagnostic accuracy of routine laboratory testing as a triage test to determine if a person has COVID-19. The reference standard could be reverse transcriptase polymerase chain reaction (RT-PCR) alone; RT-PCR plus clinical expertise or and imaging; repeated RT-PCR several days apart or from different samples; WHO and other case definitions; and any other reference standard used by the study authors. DATA COLLECTION AND ANALYSIS: Two review authors independently extracted data from each included study. They also assessed the methodological quality of the studies, using QUADAS-2. We used the 'NLMIXED' procedure in SAS 9.4 for the hierarchical summary receiver operating characteristic (HSROC) meta-analyses of tests for which we included four or more studies. To facilitate interpretation of results, for each meta-analysis we estimated summary sensitivity at the points on the SROC curve that corresponded to the median and interquartile range boundaries of specificities in the included studies. MAIN

resultsWe included 21 studies in this review, including 14,126 COVID-19 patients and 56,585 non-COVID-19 patients in total. Studies evaluated a total of 67 different laboratory tests. Although we were interested in the diagnotic accuracy of routine tests for COVID-19, the included studies used detection of SARS-CoV-2 infection through RT-PCR as reference standard. There was considerable heterogeneity between tests, threshold values and the settings in which they were applied. For some tests a positive result was defined as a decrease compared to normal vaues, for other tests a positive result was defined as an increase, and for some tests both increase and decrease may have indicated test positivity. None of the studies had either low risk of bias on all domains or low concerns for applicability for all domains. Only three of the tests evaluated had a summary sensitivity and specificity over 50%. These were: increase in interleukin-6, increase in C-reactive protein and lymphocyte count decrease. Blood count Eleven studies evaluated a decrease in white blood cell count, with a median specificity of 93% and a summary sensitivity of 25% (95% CI 8.0% to 27%; very low-certainty evidence). The 15 studies that evaluated an increase in white blood cell count had a lower median specificity and a lower corresponding sensitivity. Four studies evaluated a decrease in neutrophil count. Their median specificity was 93%, corresponding to a summary sensitivity of 10% (95% CI 1.0% to 56%; low-certainty evidence). The 11 studies that evaluated an increase in neutrophil count had a lower median specificity and a lower corresponding sensitivity. The summary sensitivity of an increase in neutrophil percentage (4 studies) was 59% (95% CI 1.0% to 100%) at median specificity (38%; very low-certainty evidence). The summary sensitivity of an increase in monocyte count (4 studies) was 13% (95% CI 6.0% to 26%) at median specificity (73%; very low-certainty evidence). The summary sensitivity of a decrease in lymphocyte count (13 studies) was 64% (95% CI 28% to 89%) at median specificity (53%; low-certainty evidence). Four studies that evaluated a decrease in lymphocyte percentage showed a lower median specificity and lower corresponding sensitivity. The summary sensitivity of a decrease in platelets (4 studies) was 19% (95% CI 10% to 32%) at median specificity (88%; low-certainty evidence). Liver function tests The summary sensitivity of an increase in alanine aminotransferase (9 studies) was 12% (95% CI 3% to 34%) at median specificity (92%; low-certainty evidence). The summary sensitivity of an increase in aspartate aminotransferase (7 studies) was 29% (95% CI 17% to 45%) at median specificity (81%) (low-certainty evidence). The summary sensitivity of a decrease in albumin (4 studies) was 21% (95% CI 3% to 67%) at median specificity (66%; low-certainty evidence). The summary sensitivity of an increase in total bilirubin (4 studies) was 12% (95% CI 3.0% to 34%) at median specificity (92%; very low-certainty evidence). Markers of inflammation The summary sensitivity of an increase in CRP (14 studies) was 66% (95% CI 55% to 75%) at median specificity (44%; very low-certainty evidence). The summary sensitivity of an increase in procalcitonin (6 studies) was 3% (95% CI 1% to 19%) at median specificity (86%; very low-certainty evidence). The summary sensitivity of an increase in IL-6 (four studies) was 73% (95% CI 36% to 93%) at median specificity (58%) (very low-certainty evidence). Other biomarkers The summary sensitivity of an increase in creatine kinase (5 studies) was 11% (95% CI 6% to 19%) at median specificity (94%) (low-certainty evidence). The summary sensitivity of an increase in serum creatinine (four studies) was 7% (95% CI 1% to 37%) at median specificity (91%; low-certainty evidence). The summary sensitivity of an increase in lactate dehydrogenase (4 studies) was 25% (95% CI 15% to 38%) at median specificity (72%; very low-certainty evidence). AUTHORS'

conclusionsAlthough these tests give an indication about the general health status of patients and some tests may be specific indicators for inflammatory processes, none of the tests we investigated are useful for accurately ruling in or ruling out COVID-19 on their own. Studies were done in specific hospitalized populations, and future studies should consider non-hospital settings to evaluate how these tests would perform in people with milder symptoms.

Indexed as

BiasBiomarkersCOVID-19COVID-19 TestingC-Reactive ProteinCreatine KinaseCreatinineDiagnostic Tests, RoutineHumansInterleukin-6Leukocyte CountLiver Function TestsL-Lactate DehydrogenaseLymphocyte CountPandemicsPlatelet CountBiomarkersC-Reactive ProteinCreatine KinaseCreatinineInterleukin-6L-Lactate Dehydrogenase

Identifiers

PMID33211319
PMCPMC8078159
OpenAlexW3101399301

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.