Evidence map›Paper›PMID 33210258›Full record

ArticleCardiovascular engineering and technology2020

First Expert Evaluation of a New Steerable Catheter in an Isolated Beating Heart.

Awaz Ali, Tamas Szili-Torok, Marco Stijnen, Paul Breedveld, Dimitra Dodou

Open access · hybridAbstract read
In one paragraph

Article in Cardiovascular engineering and technology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
0.4field-weighted citation impact, top 32% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 5 citations in OpenAlex.

  1. Review
  2. Article
  3. Review
  4. Characterization of Surgical Tools for Specific Endovascular Navigation.Cardiovascular engineering and technology · 2022
    Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 1 country.

Awaz AliBioMechanical Engineering, Delft University of Technology, Delft, Zuid-Holland, The Netherlands. a.ali@tudelft.nl.ORCID 0000-0001-6519-4836
Tamas Szili-TorokErasmus Medical Center, Electrophysiology, Rotterdam, Zuid-Holland, The Netherlands.
Marco StijnenLifeTec Group, Eindhoven, The Netherlands.
Paul BreedveldBioMechanical Engineering, Delft University of Technology, Delft, Zuid-Holland, The Netherlands.
Dimitra DodouBioMechanical Engineering, Delft University of Technology, Delft, Zuid-Holland, The Netherlands.
Delft University of Technology · NLErasmus MC · NLLifeTec Group (Netherlands) · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeIn previous studies we developed two mechanical prototypes of steerable catheters: the Sigma, which uses joysticks to actuate two steerable tip segments, and the Epsilon, which has a handle that is an enlarged version of the tip. In this study, we present a first performance evaluation of the prototypes in the cardiac environment. The evaluation was carried out by an expert user, an electrophysiologist with over 20 years of experience, to obtain insight in clinically relevant factors.

methodsTwo experiments were conducted. In the first experiment, the Sigma was used in a passive beating heart setup connected to pumps with a saline solution and camera visualization, and compared with the expert's past experience with conventional steerable catheters. In the second experiment, the Sigma was used in an active beating heart setup with blood perfusion through the coronary arteries and echo visualization, and compared with the Epsilon prototype. The prototype was evaluated through questionnaires on task performance, catheter usability, and workload. After each of the experiments, the catheter characteristics were evaluated via a survey and followed by an in-depth interview. RESULTS &

conclusionsThe expert user found the passive beating heart setup to more successful than the active beating heart setup for the purpose of this experiment, with insightful visualization while the heart was in beating condition. The steerability of the prototypes was experienced as useful and clinically relevant. Based on the questionnaires and interview we were able to identify future design improvements and developments for the steerable catheter prototypes.

Indexed as

Cardiac CathetersAnimalsCardiac CatheterizationEquipment DesignHeart RateIsolated Heart PreparationMaterials TestingModels, AnimalMyocardial ContractionSus scrofaBeating heartCatheter designEvaluationExpert opinionSteerable catheter