Reproducibility of liver iron concentration estimates in MRI through R2* measurement determined by least-squares curve fitting.

Andrew M Headley, Jared V Grice, David R Pickens

Open access · goldAbstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.4field-weighted citation impact, top 36% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Andrew M HeadleyDepartment of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, TN, USA.
Jared V GriceDepartment of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, TN, USA.
David R PickensDepartment of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, TN, USA.
Vanderbilt University Medical Center · US

Funding

Replacement and Upgrade of a 3T MR Scanner for ResearchS10OD021771 · OD · VANDERBILT UNIVERSITY MEDICAL CENTER · PI GORE, JOHN C · 2016 to 2016
$2.0M
NIH HHS S10 OD021771
6 · The paper itself

Abstract

Measuring transverse relaxation rate (R2* = 1/T2*) via MRI allows for noninvasive evaluation of multiple clinical parameters, including liver iron concentration (LIC) and fat fraction. Both fat and iron contribute to diffuse liver disease when stored in excess in the liver. This liver damage leads to fibrosis and cirrhosis with an increased risk of developing hepatocellular carcinoma. Liver iron concentration is linearly related to R2* measurements using MRI. A phantom was constructed to assess R2* quantification variability on 1.5 and 3 T MRI systems. Quantification was executed using least-squares curve fitting techniques. The phantom was created using readily available, low-cost materials. It contains four vials with R2* values that cover a clinically relevant range (100 to 420 Hz at 1.5 T). Iron content was achieved using ferric chloride solutions contained in glass vials, each affixed in a three-dimensional (3D)-printed polylactide (PLA) structure, surrounded by distilled water, all housed in a sealed acrylic cylinder. Multiple phantom stands were also 3D-printed using PLA for precise orientation of the phantom with respect to the direction of the static magnetic field. Acquisitions at different phantom angles, across multiple MRI systems, and with different pulse sequence parameters were evaluated. The variability between any two R2* measurements, taken in the same vial under these various acquisition conditions, on a 1.5 T MRI system, was <7% for each of the four vials. For 3 T MRI systems, variability was less than 14% in all cases. Variability was <6% for both 1.5 and 3 T acquisitions when unchanged pulse sequence parameters were used. The phantom can be used to mimic a range of clinically relevant levels of R2* relaxation rates, as measured using MRI. These measurements were found to be reproducible relative to the gold-standard method, liver biopsy, across several different image acquisition conditions.

Indexed as

Iron OverloadHumansIronLiverMagnetic Resonance ImagingReproducibility of ResultsIronHICiron overloadLICMR relaxometryR2* relaxometry

Identifiers

PMID33207043
PMCPMC7769411
OpenAlexW3099859241

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.