ArticleSensors (Basel, Switzerland)2020

Closed-Loop Temperature Control Based on Fiber Bragg Grating Sensors for Laser Ablation of Hepatic Tissue.

Sanzhar Korganbayev, Annalisa Orrico, Leonardo Bianchi, Martina De Landro, Alexey Wolf, Alexander Dostovalov, Paola Saccomandi

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 19 papers.

0numbers the graph read from it
0cells of the map it votes in
19citing papers in PubMed
5.6field-weighted citation impact, top 3% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

19 citing papers in PubMed, 52 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Review
  11. Article
  12. Article
  13. Review
  14. Review
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 2 countries.

Sanzhar KorganbayevDepartment of Mechanical Engineering, Politecnico di Milano Milan, 20133 Milano MI, Italy.
Annalisa OrricoDepartment of Mechanical Engineering, Politecnico di Milano Milan, 20133 Milano MI, Italy.ORCID 0000-0001-7427-5590
Leonardo BianchiDepartment of Mechanical Engineering, Politecnico di Milano Milan, 20133 Milano MI, Italy.ORCID 0000-0001-6100-0862
Martina De LandroDepartment of Mechanical Engineering, Politecnico di Milano Milan, 20133 Milano MI, Italy.ORCID 0000-0002-1778-8928
Alexey WolfLaboratory of Fiber Optics, Institute of Automation and Electrometry SB RAS, Novosibirsk 630090, Russia.ORCID 0000-0001-5176-122X
Alexander DostovalovLaboratory of Fiber Optics, Institute of Automation and Electrometry SB RAS, Novosibirsk 630090, Russia.
Paola SaccomandiDepartment of Mechanical Engineering, Politecnico di Milano Milan, 20133 Milano MI, Italy.ORCID 0000-0003-4236-8033
Politecnico di Milano · ITInstitute of Automation and Electrometry · RU

Funding

European Research Council 759159the State Budget of the Russian Federation IAE project No. AAAAA17-117062110026-3
6 · The paper itself

Abstract

Laser ablation (LA) of cancer is a minimally invasive technique based on targeted heat release. Controlling tissue temperature during LA is crucial to achieve the desired therapeutic effect in the organs while preserving the healthy tissue around. Here, we report the design and implementation of a real-time monitoring system performing closed-loop temperature control, based on fiber Bragg grating (FBG) spatial measurements. Highly dense FBG arrays (1.19 mm length, 0.01 mm edge-to-edge distance) were inscribed in polyimide-coated fibers using the femtosecond point-by-point writing technology to obtain the spatial resolution needed for accurate reconstruction of high-gradient temperature profiles during LA. The zone control strategy was implemented such that the temperature in the laser-irradiated area was maintained at specific set values (43 and 55 °C), in correspondence to specific radii (2 and 6 mm) of the targeted zone. The developed control system was assessed in terms of measured temperature maps during an ex vivo liver LA. Results suggest that the temperature-feedback system provides several advantages, including controlling the margins of the ablated zone and keeping the maximum temperature below the critical values. Our strategy and resulting analysis go beyond the state-of-the-art LA regulation techniques, encouraging further investigation in the identification of the optimal control-loop.

Indexed as

Laser TherapyTemperatureAnimalsLasersLiverclosed-loop temperature controlfeedback systemfiber Bragg grating sensorslaser ablationoptical fiberreal-time monitoringtemperature measurementsthermal ablation

Identifiers

PMID33203048
PMCPMC7697476
OpenAlexW3104528889

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.