ArticlePhysics in medicine and biology2021
Characterizing blood clots using acoustic radiation force optical coherence elastography and ultrasound shear wave elastography.
Article in Physics in medicine and biology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
14 citing papers in PubMed, 23 citations in OpenAlex.
- First Clinical Description of Coagulation of Whole Blood with Resonant Acoustic Rheometry.Diagnostics (Basel, Switzerland) · 2025Article
- A novel stress sensor enables accurate estimation of micro-scale tissue mechanics in quantitative micro-elastography.APL bioengineering · 2024Article
- Wearable bioadhesive ultrasound shear wave elastography.Science advances · 2024Article
- Analysis of friction in quantitative micro-elastography.Biomedical optics express · 2023Article
- Acoustic Force Elastography Microscopy.IEEE transactions on bio-medical engineering · 2023Article
- Estimating Thrombus Elasticity by Shear Wave Elastography to Evaluate Ultrasound Thrombolysis for Thrombus With Different Stiffness.IEEE transactions on bio-medical engineering · 2023Article
- Quantification of clot spatial heterogeneity and its impact on thrombectomy.Journal of neurointerventional surgery · 2022Article
- Clot composition characterization using diffuse reflectance spectroscopy in acute ischemic stroke.Biomedical optics express · 2022Article
- Identifying clot composition using intravascular diffuse reflectance spectroscopy in a porcine model of endovascular thrombectomy.Journal of neurointerventional surgery · 2022Article
- Experimental Evaluation of the Effectiveness of Aspiration-Based Techniques to Treat Different Types of Acute Thromboembolic Occlusions in the Femoropopliteal Vascular System Using an In Vitro Flow Model.Cardiovascular and interventional radiology · 2022Article
- Novel Human Acute Ischemic Stroke Blood Clot Analogs for In Vitro Thrombectomy Testing.AJNR. American journal of neuroradiology · 2021Article
- Intraoperative Ultrasound Shear-Wave Elastography in Focal Cortical Dysplasia Surgery.Journal of clinical medicine · 2021Article
- Characterizing thrombus with multiple red blood cell compositions by optical coherence tomography attenuation coefficient.Journal of biophotonics · 2021Article
- Ultrasound Shear Wave Elastography and Transient Optical Coherence Elastography: Side-by-Side Comparison of Repeatability and Accuracy.IEEE open journal of engineering in medicine and biology · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors at 3 institutions in 2 countries.
Funding
Abstract
Thromboembolism in a cerebral blood vessel is associated with high morbidity and mortality. Mechanical thrombectomy (MT) is one of the emergenc proceduresperformed to remove emboli. However, the interventional approaches such as aspiration catheters or stent retriever are empirically selected. An inappropriate selection of surgical devices can influence the success rate during embolectomy, which can lead to an increase in brain damage. There has been growing interest in the study of clot composition and using a priori knowledge of clot composition to provide guidance for an appropriate treatment strategy for interventional physicians. Developing imaging tools which can allow interventionalists to understand clot composition could affect management and device strategy. In this study, we investigated how clots of different compositions can be characterized by using acoustic radiation force optical coherence elastography (ARF-OCE) and compared with ultrasound shear wave elastography (SWE). Five different clots compositions using human blood were fabricated into cylindrical forms from fibrin-rich (21% red blood cells, RBCs) to RBC-rich (95% RBCs). Using the ARF-OCE and SWE, we characterized the wave velocities measured in the time-domain. In addition, the semi-analytical finite element model was used to explore the relationship between the phase velocities with various frequency ranges and diameters of the clots. The study demonstrated that the wave group velocities generally decrease as RBC content increases in ARF-OCE and SWE. The correlation of the group velocities from the OCE and SWE methods represented a good agreement as RBC composition is larger than 39%. Using the phase velocity dispersion analysis applied to ARF-OCE data, we estimated the shear wave velocities decoupling the effects of the geometry and material properties of the clots. The study demonstrated that the composition of the clots can be characterized by elastographic methods using ARF-OCE and SWE, and OCE demonstrated better ability to discriminate between clots of different RBC compositions, compared to the ultrasound-based approach, especially in clots with low RBC compositions.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.