ReviewRadiology2021
Next-Generation Hardware Advances in CT: Cardiac Applications.
Review in Radiology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 29 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
29 citing papers in PubMed, 52 citations in OpenAlex.
- What you don't see matters: dual-energy CT in emergency radiology.Japanese journal of radiology · 2026Review
- Impact of Spatial Resolution on CT Imaging of Middle Ear Prostheses: Comparison of Photon-Counting and Energy-Integrating Detectors.AJNR. American journal of neuroradiology · 2026Article
- Ultra-high spatial resolution at photon-counting computed tomography: technical insights and sustainable applications in cardiothoracic imaging.European radiology experimental · 2026Review
- Pediatric Cardiac Imaging With Second- and Third-generation Dual Source CT Scanners: Radiation Dose, and Diagnostic Accuracy in Comparison With Echocardiography and MRI-A Systematic Review and Meta-analysis.Journal of the Saudi Heart Association · 2026Review
- Low-tube-potential ultra-high-resolution coronary CTA with photon-counting detector CT for stent evaluation: a comparative feasibility study.Japanese journal of radiology · 2025Article
- Future Applications of Cardiothoracic CT.Radiology · 2025Review
- Pericoronary Adipose Tissue Attenuation in Patients with Future Acute Coronary Syndromes: The ICONIC Study.Radiology. Cardiothoracic imaging · 2025Observational
- An end-to-end neural network for 4D cardiac CT reconstruction using single-beat scans.Physics in medicine and biology · 2025Article
- Beam hardening of K-edge contrast agents: a phantom study comparing clinical energy-integrating detector and photon-counting detector CT systems.European radiology experimental · 2025Article
- Review
- Camera-on-tip endoscope forBiomedical optics express · 2025Article
- Cardiac Functional Assessment by Magnetic Resonance Imaging.Cardiology discovery · 2024Review
- Clinical Advances in Cardiovascular Computed Tomography: From Present Applications to Promising Developments.Current cardiology reports · 2024Review
- Triple-source saddle-curve cone-beam photon counting CT image reconstruction: A simulation study.Zeitschrift fur medizinische Physik · 2024Article
- Coronary artery calcification and cardiovascular outcome as assessed by intravascular OCT and artificial intelligence.Biomedical optics express · 2024Article
- Coronary computed tomography angiography for clinical practice.Japanese journal of radiology · 2024Review
- Cardiac-induced motion of the pancreas and its effect on image quality of ultrahigh-resolution CT.European radiology experimental · 2024Article
- Visualization of the lenticulostriate arteries, long insular arteries, and long medullary arteries on intra-arterial computed tomography angiography with ultrahigh resolution in patients with glioma.Acta neurochirurgica · 2023Article
- Dual-Energy CT in Cardiothoracic Imaging: Current Developments.Diagnostics (Basel, Switzerland) · 2023Review
- Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 3 institutions in 3 countries.
Funding
Abstract
Impending major hardware advances in cardiac CT include three areas: ultra-high-resolution (UHR) CT, photon-counting CT, and phase-contrast CT. Cardiac CT is a particularly demanding CT application that requires a high degree of temporal resolution, spatial resolution, and soft-tissue contrast in a moving structure. In this review, cardiac CT is used to highlight the strengths of these technical advances. UHR CT improves visualization of calcified and stented vessels but may result in increased noise and radiation exposure. Photon-counting CT uses multiple photon energies to reduce artifacts, improve contrast resolution, and perform material decomposition. Finally, phase-contrast CT uses x-ray refraction properties to improve spatial and soft-tissue contrast. This review describes these hardware advances in CT and their relevance to cardiovascular imaging.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.