Evidence map›Paper›PMID 33200562›Full record

ArticleOrthopaedic surgery2020

Effect of Strain Rates on Failure of Mechanical Properties of Lumbar Intervertebral Disc Under Flexion.

Kun Li, Shi-Jie Zhang, Cheng-Fei Du, Ji-Zhe Zhao, Qing Liu, Chun-Qiu Zhang, Yan-Fang Sun

Abstract read
In one paragraph

Article in Orthopaedic surgery, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Review
  2. Review
  3. Review
  4. Article
  5. Article
  6. Article
  7. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Kun LiTianjin Key Laboratory of Film Electronic and Communication Device, Tianjin University of Technology, Tianjin, China.ORCID https://orcid.org/0000-0002-8804-3624
Shi-Jie ZhangTianjin Key Laboratory of Film Electronic and Communication Device, Tianjin University of Technology, Tianjin, China.
Cheng-Fei DuTianjin Key Laboratory for Advanced Mechatronic System Design and Intelligent Control, Tianjin University of Technology, Tianjin, China.ORCID https://orcid.org/0000-0001-7486-1848
Ji-Zhe ZhaoTianjin Key Laboratory for Advanced Mechatronic System Design and Intelligent Control, Tianjin University of Technology, Tianjin, China.
Qing LiuTianjin Key Laboratory for Advanced Mechatronic System Design and Intelligent Control, Tianjin University of Technology, Tianjin, China.ORCID https://orcid.org/0000-0001-5629-7091
Chun-Qiu ZhangTianjin Key Laboratory for Advanced Mechatronic System Design and Intelligent Control, Tianjin University of Technology, Tianjin, China.
Yan-Fang SunTianjin Key Laboratory for Advanced Mechatronic System Design and Intelligent Control, Tianjin University of Technology, Tianjin, China.

Funding

National Natural Science Foundation of China 11802207Natural Science Foundation of Tianjin City 18YFZCSY00890Natural Science Foundation of Tianjin City 18ZXSGSY00010
6 · The paper itself

Abstract

objectiveTo evaluate the strain-rate-dependent viscoelastic properties of the intervertebral disc by in vitro experiments.

methodThe biomechanical experiments were conducted from September 2019 to December 2019. The lumbar spines of sheep were purchased within 4-6 hours from the local slaughterhouse, and the intervertebral disc samples were divided into three groups. In rupture group, the samples were used to test the mechanical behavior of the intervertebral disc rupture at different strain rates. In fatigue injury group, the samples were used to test the mechanical behavior of fatigue injury on the intervertebral disc under different strain rates. In internal displacement group, the samples were used to test the internal displacement distribution of the intervertebral disc at different strain rates by applying an optimized digital image correlation (DIC) technique.

resultsBoth the yielding and cracking phenomenon occurs at fast and medium loading rates, while only the yielding phenomenon occurs at a slow loading rate. The yield stress, compressive strength, and elastic modulus all increase with the increase of the strain rate, while the yield strain decreases with the increase of the strain rate. The logarithm of the elastic modulus in the intervertebral disc is approximately linear with the logarithm of the strain rate under different strain rates. Both before and after fatigue loading, the stiffness in the loading and unloading curves of the intervertebral disc is inconsistent, forming a hysteresis loop, which is caused by the viscoelastic effect. The strain rate has no significant effect on the internal displacement distribution of the intervertebral disc. Based on the experimental data, the constitutive relationship of the intervertebral disc at different strain rates is obtained. The fitting curves are well coupled with the experimental data, while the fitting parameters are approximately linear with the logarithm of the strain rate.

conclusionsThese experiments indicate that the strain rate has a significant effect on the mechanical behavior of the intervertebral disc rupture and fatigue injury, while the constitutive equation can predict the rate-dependent mechanical behavior of lumbar intervertebral disc under flexion very well. These results have important theoretical guiding significance for preventing lumbar disc herniation in daily life.

Indexed as

AnimalsBiomechanical PhenomenaCompressive StrengthIntervertebral DiscLumbar VertebraeSheepConstitutive modelFatigue injuryLumbar disc herniationRate-dependentViscoelastic

Identifiers

PMID33200562
PMCPMC7767776

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.