Evidence map›Paper›PMID 33200301›Full record

ArticleJournal of artificial organs : the official journal of the Japanese Society for Artificial Organs2021

In vitro blood compatibility evaluation method: incubating while rotating hemodialyzers filled with fresh human blood.

Kinue Kamata, Yoshihiro Hatanaka, Hiromi Tanaka, Satoru Inoue, Yusuke Tokimizu, Sayuri Tanba, Yuki Kishikawa, Toshinori Koizumi

Open access · hybridAbstract read
In one paragraph

Article in Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.1field-weighted citation impact, top 47% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

Kinue KamataMedical Technology and Material Laboratory, Research and Business Development Division, Asahi Kasei Medical Co., LTD., 2-1, Samejima, Fuji-City, Shizuoka, 416-8501, Japan. shibata.kn@om.asahi-kasei.co.jp.
Yoshihiro HatanakaMedical Technology and Material Laboratory, Research and Business Development Division, Asahi Kasei Medical Co., LTD., 2-1, Samejima, Fuji-City, Shizuoka, 416-8501, Japan. hatanaka.yc@om.asahi-kasei.co.jp.ORCID http://orcid.org/0000-0001-9669-0787
Hiromi TanakaMedical Technology and Material Laboratory, Research and Business Development Division, Asahi Kasei Medical Co., LTD., 2-1, Samejima, Fuji-City, Shizuoka, 416-8501, Japan.
Satoru InoueMedical Technology and Material Laboratory, Research and Business Development Division, Asahi Kasei Medical Co., LTD., 2-1, Samejima, Fuji-City, Shizuoka, 416-8501, Japan.
Yusuke TokimizuMedical Technology and Material Laboratory, Research and Business Development Division, Asahi Kasei Medical Co., LTD., 2-1, Samejima, Fuji-City, Shizuoka, 416-8501, Japan.
Sayuri TanbaMedical Technology and Material Laboratory, Research and Business Development Division, Asahi Kasei Medical Co., LTD., 2-1, Samejima, Fuji-City, Shizuoka, 416-8501, Japan.
Yuki KishikawaMedical Technology and Material Laboratory, Research and Business Development Division, Asahi Kasei Medical Co., LTD., 2-1, Samejima, Fuji-City, Shizuoka, 416-8501, Japan.
Toshinori KoizumiMedical Technology and Material Laboratory, Research and Business Development Division, Asahi Kasei Medical Co., LTD., 2-1, Samejima, Fuji-City, Shizuoka, 416-8501, Japan.
Asahi Kasei (Japan) · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

One of the often-used methods for in vitro evaluation of the blood compatibility of hemodialysis membranes is the circulation of human blood through a miniaturized hemodialyzer. The use of a rather small amount of human blood in its evaluation is one advantage of this method. However, because it is manufactured by a different process than actual ones, a miniaturized hemodialyzer membrane cannot always preserve the properties of actual hemodialyzers. To address this problem, we established a new experimental method that uses a relatively small amount of human blood and actual dialyzers. In this method, a test hemodialyzer and a control hemodialyzer filled with human blood obtained from the same donor is slowly rotated to prevent spontaneous blood cell sedimentation for 4 h at 37 °C. By use of this method, we were able to compare blood compatibility between a polysulfone (PS) membrane and a vitamin E (VE)-bonded PS membrane in terms of their relative antithrombotic, antioxidative, and anti-inflammatory properties. Consistent with many previous reports, the results clearly showed that compared with the PS membrane, VE-bonded PS membrane is more blood compatible. These findings suggest that our method is applicable, at least to in vitro blood compatibility evaluation of PS type dialysis membranes.

Indexed as

Kidneys, ArtificialAntioxidantsHumansMembranes, ArtificialRenal DialysisVitamin EAntioxidantsMembranes, ArtificialVitamin EAnti-inflammatory propertyAntioxidative propertyAntithrombotic propertyBlood compatibilityVitamin E-bonded polysulfone membrane

Identifiers

PMID33200301
PMCPMC8380571
OpenAlexW3100016412

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.