Evidence map›Paper›PMID 33199768›Full record

ArticleScientific reports2020

Development and in vitro validation of flexible intraretinal probes.

V Rincón Montes, J Gehlen, S Ingebrandt, W Mokwa, P Walter, F Müller, A Offenhäusser

Open access · goldAbstract readComparative Study
In one paragraph

Article in Scientific reports, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
0.8field-weighted citation impact, top 32% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 17 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Review
  6. Article
  7. Article
  8. Article
  9. Review
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

V Rincón MontesBioelectronics, Institute of Biological Information Processing-3, Forschungszentrum Jülich, Jülich, Germany.
J GehlenMolecular and Cellular Physiology, Institute of Biological Information Processing-1, Forschungszentrum Jülich, Jülich, Germany.
S IngebrandtInstitute of Materials in Electrical Engineering 1, RWTH Aachen University, Aachen, Germany.
W MokwaInstitute of Materials in Electrical Engineering 1, RWTH Aachen University, Aachen, Germany.
P WalterDepartment of Ophthalmology, RWTH Aachen University, Aachen, Germany.
F MüllerMolecular and Cellular Physiology, Institute of Biological Information Processing-1, Forschungszentrum Jülich, Jülich, Germany.
A OffenhäusserBioelectronics, Institute of Biological Information Processing-3, Forschungszentrum Jülich, Jülich, Germany. a.offenhaeusser@fz-juelich.de.
RWTH Aachen University · DEForschungszentrum Jülich · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The efforts to improve the treatment efficacy in blind patients with retinal degenerative diseases would greatly benefit from retinal activity feedback, which is lacking in current retinal implants. While the door for a bidirectional communication device that stimulates and records intraretinally has been opened by the recent use of silicon-based penetrating probes, the biological impact induced by the insertion of such rigid devices is still unknown. Here, we developed for the first time, flexible intraretinal probes and validated in vitro the acute biological insertion impact in mouse retinae compared to standard silicon-based probes. Our results show that probes based on flexible materials, such as polyimide and parylene-C, in combination with a narrow shank design 50 µm wide and 7 µm thick, and the use of insertion speeds as high as 187.5 µm/s will successfully penetrate the retina, reduce the footprint of the insertion to roughly 2 times the cross-section of the probe, and induce low dead cell counts, while keeping the vitality of the tissue and recording the neural activity at different depths.

Indexed as

AnimalsElectrodes, ImplantedEquipment DesignFeedback, PhysiologicalMaterials TestingMiceMicroelectrodesPhantoms, ImagingPliabilityRetinaSiliconSilicon

Identifiers

PMID33199768
PMCPMC7669900
OpenAlexW3100415009

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked