Evidence map›Paper›PMID 33198769›Full record

ArticleBiomedical engineering online2020

Investigation of safety for electrochemotherapy and irreversible electroporation ablation therapies in patients with cardiac pacemakers.

Tomaz Jarm, Tadej Krmac, Ratko Magjarevic, Bor Kos, Helena Cindric, Damijan Miklavcic

Open access · goldAbstract read
In one paragraph

Article in Biomedical engineering online, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed, 1 pooled it
1.6field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 1 synthesis or guideline pooled it, 17 citations in OpenAlex.

  1. Pooled it
  2. Pulsed field ablation in patients with cardiac implantable electronic devices: an ex vivo assessment of safety.Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2026
    Article
  3. Safety and feasibility of pulsed field ablation with a pentaspline catheter in patients with cardiac implantable electronic devices: a multicentre experience.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2025
    Article
  4. Article
  5. Review
  6. Article
  7. EHRA consensus on prevention and management of interference due to medical procedures in patients with cardiac implantable electronic devices.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2022
    Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 2 countries.

Tomaz JarmUniversity of Ljubljana, Faculty of Electrical Engineering, Trzaska 25, 1000, Ljubljana, Slovenia. tomaz.jarm@fe.uni-lj.si.ORCID http://orcid.org/0000-0002-9218-1755
Tadej KrmacUniversity of Ljubljana, Faculty of Electrical Engineering, Trzaska 25, 1000, Ljubljana, Slovenia.
Ratko MagjarevicUniversity of Zagreb, Faculty of Electrical Engineering and Computing, Unska 3, 10000, Zagreb, Croatia.
Bor KosUniversity of Ljubljana, Faculty of Electrical Engineering, Trzaska 25, 1000, Ljubljana, Slovenia.
Helena CindricUniversity of Ljubljana, Faculty of Electrical Engineering, Trzaska 25, 1000, Ljubljana, Slovenia.
Damijan MiklavcicUniversity of Ljubljana, Faculty of Electrical Engineering, Trzaska 25, 1000, Ljubljana, Slovenia.
University of Ljubljana · SIUniversity of Zagreb · HR

Funding

Javna Agencija za Raziskovalno Dejavnost RS BI-HR/16-17-039Javna Agencija za Raziskovalno Dejavnost RS I0-0022Javna Agencija za Raziskovalno Dejavnost RS P2-0249
6 · The paper itself

Abstract

backgroundThe effectiveness of electrochemotherapy of tumors (ECT) and of irreversible electroporation ablation (IRE) depends on different mechanisms and delivery protocols. Both therapies exploit the phenomenon of electroporation of the cell membrane achieved by the exposure of the cells to a series of high-voltage electric pulses. Electroporation can be fine-tuned to be either reversible or irreversible, causing the cells to either survive the exposure (in ECT) or not (in IRE), respectively. For treatment of tissues located close to the heart (e.g., in the liver), the safety of electroporation-based therapies is ensured by synchronizing the electric pulses with the electrocardiogram. However, the use of ECT and IRE remains contraindicated for patients with implanted cardiac pacemakers if the treated tissues are located close to the heart or the pacemaker. In this study, two questions are addressed: can the electroporation pulses interfere with the pacemaker; and, can the metallic housing of the pacemaker modify the distribution of electric field in the tissue sufficiently to affect the effectiveness and safety of the therapy?

resultsThe electroporation pulses induced significant changes in the pacemaker ventricular pacing pulse only for the electroporation pulses delivered during the pacing pulse itself. No residual effects were observed on the pacing pulses following the electroporation pulses for all tested experimental conditions. The results of numerical modeling indicate that the presence of metal-encased pacemaker in immediate vicinity of the treatment zone should not impair the intended effectiveness of ECT or IRE even when the casing is in direct contact with one of the active electrodes. Nevertheless, the contact between the casing and the active electrode should be avoided due to significant tissue heating at the site of the other active electrode for the IRE protocol and may cause the pulse generator to fail to deliver the pulses due to excessive current draw.

conclusionsThe observed effects of electroporation pulses delivered in close vicinity of the pacemaker or its electrodes do not indicate adverse consequences for either the function of the pacemaker or the treatment outcome. These findings should contribute to making electroporation-based treatments accessible also to patients with implanted cardiac pacemakers.

Indexed as

ElectroporationModels, TheoreticalPacemaker, ArtificialSafetyAblation TechniquesElectrochemotherapyElectrodesHumansCardiac pacemakerElectrochemotherapy of tumorsExperimental workImplantable devicesIrreversible electroporationNon-thermal ablation therapyNumerical modelingSafety

Identifiers

PMID33198769
PMCPMC7667796
OpenAlexW3100176917

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.