ArticleSensors (Basel, Switzerland)2020
A Low-Cost Calibration Method for Low-Cost MEMS Accelerometers Based on 3D Printing.
Article in Sensors (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed.
- Simple Calibration of Three-Axis Accelerometers with Freely Rotating Vertical Bench.Sensors (Basel, Switzerland) · 2025Article
- 3D printing of micro-nano devices and their applications.Microsystems & nanoengineering · 2025Review
- A Scale Factor Calibration Method for MEMS Resonant Accelerometers Based on Virtual Accelerations.Micromachines · 2023Article
- A Bond-Wire Drift Offset Minimized Capacitance-to-Digital Interface for MEMS Accelerometer with Gain-Enhanced VCO-Based Quantization and Nested Digital Chopping Feedback Loops.Sensors (Basel, Switzerland) · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
Abstract
A ubiquitous sensor in embedded systems is the accelerometer, as it enables a range of applications. However, accelerometers experience nonlinearities in their outputs caused by error terms and axes misalignment. These errors are a major concern because, in applications such as navigations systems, they accumulate over time, degrading the position accuracy. Through a calibration procedure, the errors can be modeled and compensated. Many methods have been proposed; however, they require sophisticated equipment available only in laboratories, which makes them complex and expensive. In this article, a simple, practical, and low-cost calibration method is proposed. It uses a 3D printed polyhedron, benefiting from the popularisation and low-cost of 3D printing in the present day. Additionally, each polyhedron could hold as much as 14 sensors, which can be calibrated simultaneously. The method was performed with a low-cost sensor and it significantly reduced the root-mean-square error (RMSE) of the sensor output. The RMSE was compared with the reported in similar proposals, and our method resulted in higher performance. The proposal enables accelerometer calibration at low-cost, and anywhere and anytime, not only by experts in laboratories. Compensating the sensor's inherent errors thus increases the accuracy of its output.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.