Evidence map›Paper›PMID 33195121›Full record

ArticleFrontiers in bioengineering and biotechnology2020

Hemodynamic Analysis of VenaTech Convertible Vena Cava Filter Using Computational Fluid Dynamics.

Jingying Wang, Wen Huang, Yue Zhou, Fangzhou Han, Dong Ke, Chunhian Lee

Open access · goldAbstract read
In one paragraph

Article in Frontiers in bioengineering and biotechnology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
0.4field-weighted citation impact, top 32% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 12 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Jingying WangSchool of Energy and Power Engineering, Shandong University, Jinan, China.
Wen HuangThe First Affiliated Hospital of Chongqing Medical University, Chongqing, China.
Yue ZhouSchool of Aeronautical Science and Engineering, Beihang University, Beijing, China.
Fangzhou HanSchool of Energy and Power Engineering, Shandong University, Jinan, China.
Dong KeThe First Affiliated Hospital of Chongqing Medical University, Chongqing, China.
Chunhian LeeSchool of Energy and Power Engineering, Shandong University, Jinan, China.
Shandong University · CNChongqing Medical University · CNBeihang University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The VenaTech convertible filter (VTCF) has been widely used as an inferior vena cava (IVC) filter to prevent fatal pulmonary embolism in patients. However, its hemodynamics that greatly affect the filter efficacy and IVC patency are still unclear. This paper uses computational fluid dynamics with the Carreau model to simulate the non-Newtonian blood flows around the VTCF respectively deployed in the normal, reverse and three converted states in an IVC model. The results show that the prothrombotic stagnation zones are observed downstream from the normal, reverse and small open VTCFs, with the streamwise length is nearly eight times the IVC diameter. The no-slip boundary conditions of the thin-wire VTCF arms lead to the "viscous block" effect. The viscous block accelerates the blood flow by 5-15% inside the IVC and enhances the filter wall shear stress up to nearly 20 times that of the IVC only, which contributes to clot capture and thrombus lysis. The relative flow resistance is defined to evaluate the filter-induced resistance on the IVC blood flow that can be regarded as an index of IVC patency with the filter deployment. The flow resistance of the normal VTCF deployment increases dramatically by more than 60% compared with that of the IVC only and is a little higher (6%) than that of the reverse case. As the VTCF converts to a fully open configuration, the flow resistance gradually decreases to that of no filter. This work shows that even very thin VTCF arms can result in the viscous block effect and may cause significant hemodynamic impacts on clot capture, potential thrombosis and flow impedance inside the IVC. The present study also shows that CFD is a valuable and feasible

Indexed as

computational fluid dynamicsdeep vein thrombosishemodynamicsinferior vena cava filterVenaTech convertible filter

Identifiers

PMID33195121
PMCPMC7661937
OpenAlexW3097714533

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.