Evidence map›Paper›PMID 33194616›Full record

ArticleFrontiers in oncology2020

Impact of Positioning Errors on the Dosimetry of Breath-Hold-Based Volumetric Arc Modulated and Tangential Field-in-Field Left-Sided Breast Treatments.

Yanqun Zhao, Peng Diao, Da Zhang, Juxiang Wu, Xin Xin, Davide Fontanarosa, Min Liu, Jie Li, Lucia Clara Orlandini

Abstract read
In one paragraph

Article in Frontiers in oncology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Yanqun ZhaoDepartment of Radiation Oncology, Sichuan Cancer Hospital and Research Institute, Chengdu, China.
Peng DiaoDepartment of Radiation Oncology, Sichuan Cancer Hospital and Research Institute, Chengdu, China.
Da ZhangDepartment of Radiation Oncology, Sichuan Cancer Hospital and Research Institute, Chengdu, China.
Juxiang WuDepartment of Radiation Oncology, Sichuan Cancer Hospital and Research Institute, Chengdu, China.
Xin XinDepartment of Radiation Oncology, Sichuan Cancer Hospital and Research Institute, Chengdu, China.
Davide FontanarosaSchool of Clinical Sciences, Queensland University of Technology, Brisbane, QLD, Australia.
Min LiuDepartment of Radiation Oncology, Sichuan Cancer Hospital and Research Institute, Chengdu, China.
Jie LiDepartment of Radiation Oncology, Sichuan Cancer Hospital and Research Institute, Chengdu, China.
Lucia Clara OrlandiniDepartment of Radiation Oncology, Sichuan Cancer Hospital and Research Institute, Chengdu, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Heart diseases and cardiovascular events are well-known side effects in left-sided breast irradiation. Deep inspiration breath hold (BH) combined with fast delivery techniques such as volumetric modulated arc therapy (VMAT) or tangential field-in-field (TFiF) can serve as a valuable solution to reduce the dose to the heart. This study aims to compare the impact of positioning errors in VMAT and TFiF plans for BH left-sided breast treatments. Fifteen left-sided breast patients treated in BH with TFiF technique were included in this retrospective study. For each patient, a second plan with VMAT technique was optimized. Eighteen setup variations were introduced in each of these VMAT and TFiF reference plans, shifting the isocenter along six different directions by 3, 5, and 10 mm. A total of 540 perturbed plans, 270 for each technique, were recalculated and analyzed. The dose distributions on the target and organs at risk obtained in the different perturbed scenarios were compared with the reference scenarios, using as dosimetric endpoints the dose-volume histograms (DVH). The results were compared using the Wilcoxon test. Comparable plan quality was obtained for the reference VMAT and TFiF plans, except for low doses to organs at risk for which higher values (p < 0.05) were obtained for VMAT plans. For TFiF plans, perturbations of the isocenter position of 3, 5, or 10 mm produced mean deviations of the target DVH dosimetric parameters up to -0.5, -1.0, and -5.2%, respectively; VMAT plans were more sensitive to positioning errors resulting in mean deviations up to -0.5, -4.9, and -13.9%, respectively, for the same magnitude of the above mentioned perturbations. For organs at risk, only perturbations along the left, posterior, and inferior directions resulted in dose increase with a maximum deviation of +2% in the DVH dosimetric parameters. A notable exception were low doses to the left lung and heart for 10 mm isocenter shifts for which the mean differences ranged between +2.7 and +4.1%. Objective information on how external stresses affect the dosimetry of the treatment is the first step towards personalized radiotherapy.

Indexed as

breath holdleft-sided breastradiotherapytangential fieldvolumetric modulated radiation therapy

Identifiers

PMID33194616
PMCPMC7658584

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.