Evidence map›Paper›PMID 33194248›Full record

ArticleBiomedical engineering letters2020

Control strategy with multivariable fault tolerance module for automatic intravenous anesthesia.

Bhavina Patel, Hirenkumar Patel, Divyang Shah, Alpesh Sarvaia

Open access · greenAbstract read
In one paragraph

Article in Biomedical engineering letters, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.3field-weighted citation impact, top 42% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 5 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Bhavina PatelDepartment of Electrical Engineering, Sardar Vallabhbhai National Institute of Technology, Surat, India.ORCID 0000-0003-0669-6224
Hirenkumar PatelDepartment of Electrical Engineering, Sardar Vallabhbhai National Institute of Technology, Surat, India.
Divyang ShahSurat Municipal Institute of Medical Education and Research (SMIMER), Surat, India.
Alpesh SarvaiaU. N. Mehta Institute of Cardiology and Research, Ahmedabad, India.
Sardar Vallabhbhai National Institute of Technology Surat · INAhmedabad Civil Hospital · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In the anesthesia automation, an automatic propofol infusion system uses Bi-spectral Index Signal (BIS) as a primary feedback signal to manipulate propofol dose. However, the BIS signal may be suspended for some time due to poor EEG signal quality, noise, and many other factors. Therefore, BIS signal failure may be the main cause of inadequate propofol infusion. This fact motivates the need for integration of multivariable fault tolerance module (MFTM) and fractional-order Smith predictor controller to avoid adverse reactions of inadequate propofol dosing during BIS failure. Smith Predictor control strategy is sufficiently robust to predict feedback BIS during BIS failure via patient pharmacological modeled BIS. However, modeled BIS may not provide a guarantee of adequate propofol infusion during BIS failure and especially in the presence of hypotension and hypertension. Thus, the proposed control strategy is designed with MFTM to detect BIS sensor fault and to estimate feedback BIS during BIS failure. Further, the proposed control strategy is designed with a multivariable pharmacological patient model to analyze the cross effect of propofol infusion on BIS and hemodynamic variables. The robustness of the proposed control strategy is tested in the presence of noxious surgical stimulation, BIS sensor fault and heavy hemodynamic disturbance. The pharmacological parameters and recorded signals of 30 patients during various surgeries have been used to validate simulated results. The performance of the proposed control strategy assures optimization and smooth propofol infusion during BIS failure. The proposed system provides stability for a wide range of physiological parameters range. The proposed scheme maintains smooth BIS and MAP signal despite the delay, BIS sensor fault, and surgical disturbances.

Indexed as

Bi-spectral Index Signal (BIS)Depth of anesthesia (DOA)Mean arterial pressure (MAP)Multivariable fault tolerance module (MFTM)Propofol

Identifiers

PMID33194248
PMCPMC7655894
OpenAlexW3049137881

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.