Evidence map›Paper›PMID 33193944›Full record

ArticleScanning2020

Surface Characterization and Corrosion Resistance of Biomedical AZ31 Mg Alloy Treated by Microarc Fluorination.

Lin Sun, Bing Cheng Zhao, Teng Wang, Jia Yi Cui, ShuXin Zhang, Feng Li, Qianqian Zhang, HongXin Cai, Heng Bo Jiang, Eui-Seok Lee

Open access · hybridAbstract read
In one paragraph

Article in Scanning, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
0.4field-weighted citation impact, top 43% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 13 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Fluoride Coatings on Magnesium Alloy Implants.Bioinorganic chemistry and applications · 2022
    Review
  5. Scanning · 2021
    Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 2 institutions in 2 countries.

Lin SunStomatological Materials Laboratory, School of Stomatology, Shandong First Medical University & Shandong Academy of Medical Sciences, Tai'an, Shandong 271016, China.
Bing Cheng ZhaoStomatological Materials Laboratory, School of Stomatology, Shandong First Medical University & Shandong Academy of Medical Sciences, Tai'an, Shandong 271016, China.
Teng WangStomatological Materials Laboratory, School of Stomatology, Shandong First Medical University & Shandong Academy of Medical Sciences, Tai'an, Shandong 271016, China.
Jia Yi CuiStomatological Materials Laboratory, School of Stomatology, Shandong First Medical University & Shandong Academy of Medical Sciences, Tai'an, Shandong 271016, China.
ShuXin ZhangStomatological Materials Laboratory, School of Stomatology, Shandong First Medical University & Shandong Academy of Medical Sciences, Tai'an, Shandong 271016, China.
Feng LiStomatological Materials Laboratory, School of Stomatology, Shandong First Medical University & Shandong Academy of Medical Sciences, Tai'an, Shandong 271016, China.
Qianqian ZhangShandong Liming Institute of Technology and Vocational College, Tai'an, Shandong 271000, China.
HongXin CaiStomatological Materials Laboratory, School of Stomatology, Shandong First Medical University & Shandong Academy of Medical Sciences, Tai'an, Shandong 271016, China.
Heng Bo JiangStomatological Materials Laboratory, School of Stomatology, Shandong First Medical University & Shandong Academy of Medical Sciences, Tai'an, Shandong 271016, China.ORCID https://orcid.org/0000-0002-2514-2633
Eui-Seok LeeDepartment of Oral and Maxillofacial Surgery, Graduate School of Clinical Dentistry, Korea University, Seoul 08308, Republic of Korea.ORCID https://orcid.org/0000-0002-1818-1140
Shandong First Medical University · CNKorea University · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The application prospect of biodegradable materials is being studied extensively. However, the high corrosion rate and its alloys in body fluids have been major limitations of the application of pure Mg (magnesium). To improve corrosion resistance of biodegradable AZ31 Mg alloy, we adopted microarc fluorination within a voltage range of 100-300 V in 46% hydrofluoric acid. To obtain morphologies, chemical compositions, and structural characteristics, field-emission scanning electron microscopy (FE-SEM), energy-dispersive X-ray spectroscopy (EDS), and X-ray diffraction (XRD) were performed, respectively. Results showed that the coating was mainly composed of MgF

Indexed as

AlloysBody FluidsCoated Materials, BiocompatibleCorrosionMagnesiumMicroscopy, Electron, ScanningSpectrometry, X-Ray EmissionSurface PropertiesX-Ray DiffractionAlloysCoated Materials, BiocompatibleMagnesiumMg-Al-Zn-Mn-Si-Cu alloy

Identifiers

PMID33193944
PMCPMC7641723
OpenAlexW3096054302

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.