Evidence map›Paper›PMID 33185051›Full record

ArticleJournal of biomedical optics2020

Theoretical lateral and axial sensitivity limits and choices of molecular reporters for Cherenkov-excited luminescence in tissue during x-ray beam scanning.

Ethan P M LaRochelle, Brian W Pogue

Open access · goldAbstract read
In one paragraph

Article in Journal of biomedical optics, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.1field-weighted citation impact, top 48% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

Ethan P M LaRochelleThayer School of Engineering, Dartmouth College, Hanover, New Hampshire, United States.
Brian W PogueThayer School of Engineering, Dartmouth College, Hanover, New Hampshire, United States.
Dartmouth College · US

Funding

Translational Engineering in Cancer (TEC)P30CA023108 · NCI · DARTMOUTH COLLEGE · PI Fred W Kolling IV · 1985 to 2026
$91.3M
Cerenkov excited luminescence sheet imaging (CELSI)R01EB024498 · NIBIB · DARTMOUTH COLLEGE · PI POGUE, BRIAN WILLIAM · 2017 to 2020
$2.2M
NCI NIH HHS P30 CA023108NIBIB NIH HHS R01 EB024498
6 · The paper itself

Abstract

purposeUnlike fluorescence imaging utilizing an external excitation source, Cherenkov emissions and Cherenkov-excited luminescence occur within a medium when irradiated with high-energy x-rays. Methods to improve the understanding of the lateral spread and axial depth distribution of these emissions are needed as an initial step to improve the overall system resolution.

methodsMonte Carlo simulations were developed to investigate the lateral spread of thin sheets of high-energy sources and compared to experimental measurements of similar sources in water. Additional simulations of a multilayer skin model were used to investigate the limits of detection using both 6- and 18-MV x-ray sources with fluorescence excitation for inclusion depths up to 1 cm.

resultsSimulations comparing the lateral spread of high-energy sources show approximately 100  ×   higher optical yield from electrons than photons, although electrons showed a larger penumbra in both the simulations and experimental measurements. Cherenkov excitation has a roughly inverse wavelength squared dependence in intensity but is largely redshifted in excitation through any distance of tissue. The calculated emission spectra in tissue were convolved with a database of luminescent compounds to produce a computational ranking of potential Cherenkov-excited luminescence molecular contrast agents.

conclusionsModels of thin x-ray and electron sources were compared with experimental measurements, showing similar trends in energy and source type. Surface detection of Cherenkov-excited luminescence appears to be limited by the mean free path of the luminescence emission, where for the given simulation only 2% of the inclusion emissions reached the surface from a depth of 7 mm in a multilayer tissue model.

Indexed as

LuminescencePhotonsMonte Carlo MethodPhantoms, ImagingX-RaysCherenkov emissionsCherenkov-excited luminescencecloud computingmedical physicsMonte Carlo modelingradiation therapytissue optics

Identifiers

PMID33185051
PMCPMC7658603
OpenAlexW3104088790

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.