ArticleAmerican journal of otolaryngology
Characterization of patient head motion in otologic surgery: Implications for TEES.
Article in American journal of otolaryngology. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 2 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 2 institutions in 1 country.
Funding
Abstract
purposeMiddle ear disease is increasingly being managed via transcanal endoscopic ear surgery (TEES). A limitation of TEES is that it restricts the surgeon to single-handed dissection. One solution to this would be an endoscope holder to facilitate two-handed dissection. Current endoscope holders are stationary, and can cause potential damage from endoscope contact with the ossicles or ear canal if unintended head motion occurs from inadequate anesthetic. A dynamic device that could detect and react to patient motion would mitigate these concerns, but currently there is little formal characterization of the frequency, velocity and acceleration of unintended patient head motion during otologic procedures performed under general anesthesia. The present study aims to characterize intraoperative patient head motion kinematics during cases utilizing TEES. MATERIALS AND
methodsThis is a prospective study of adults undergoing otologic procedures performed with general anesthesia and without paralysis. Head motion was characterized using a nine-axis inertial measurement unit (IMU), (LPMS-B2, Life Performance Research) mounted to each patient's forehead for the procedure duration.
resultsData was collected across 10 cases; 50% of patients were female and mean age was 50 ± 14 years. There was observed patient head motion in 40% of cases with maximum linear acceleration of 0.75 m/s
conclusionsPatient movement during otologic procedures was commonly observed, demonstrating the need for a dynamic holder to allow two-handed TEES. Results from this study are the first objective characterization of patient head motion kinematics during otologic procedures performed under general anesthesia.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.