ArticleTherapeutic advances in gastroenterology2020
Four-dimensional impedance manometry derived from esophageal high-resolution impedance-manometry studies: a novel analysis paradigm.
Article in Therapeutic advances in gastroenterology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT06883175 (Evolution of the Chicago Classification), which is not on this map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Evolution of the Chicago Classification: Bridging Physiology and Mechanics
Who cites it
6 citing papers in PubMed.
- Biomechanical Assessment During High-Resolution Impedance Manometry Enhances Characterization of Inconclusive Esophagogastric Junction Outflow Obstruction.Neurogastroenterology and motility · 2026Article
- Addressing Gaps in the Chicago Classification Version 4.0: Defining an Optimal Intrabolus Pressure Measurement on Esophageal Manometry.Neurogastroenterology and motility · 2026Article
- When Manometry and Functional Lumen Imaging Probe Disagree: The Current Limitations of the Chicago Classification Version 4.0 and Probable Extended Indications of Functional Lumen Imaging Probe.Journal of neurogastroenterology and motility · 2025Review
- Assessing Treatment Outcomes in Achalasia Using 4-Dimensional High-resolution Impedance Manometry.Journal of neurogastroenterology and motility · 2025Article
- Normative values of intra-bolus pressure and esophageal compliance based on 4D high-resolution impedance manometry.Neurogastroenterology and motility · 2022Article
- A Comparative Assessment of the Diagnosis of Swallowing Impairment and Gastroesophageal Reflux in Canines and Humans.Frontiers in veterinary science · 2022Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
backgroundThis study aimed to introduce a novel analysis paradigm, referred to as 4-dimensional (4D) manometry based on biophysical analysis; 4D manometry enables the visualization of luminal geometry of the esophagus and esophagogastric junction (EGJ) using high-resolution-impedance-manometry (HRIM) data.
methodsHRIM studies from two asymptomatic controls and one type-I achalasia patient were analyzed. Concomitant fluoroscopy images from one control subject were used to validate the calculated temporal-spatial luminal radius and time-history of intraluminal bolus volume and movement. EGJ analysis computed diameter threshold for emptying, emptying time, flow rate, and distensibility index (DI), which were compared with bolus flow time (BFT) analysis.
resultsFor normal control, calculated volumes for 5 ml swallows were 4.1 ml-6.7 ml; for 30 ml swallows 21.3 ml-21.8 ml. With type-I achalasia, >4 ml of intraesophageal bolus residual was present both pre- and post-swallow. The four phases of bolus transit were clearly illustrated on the time-history of bolus movement, correlating well with the fluoroscopic images. In the control subjects, the EGJ diameter threshold for emptying was 8 mm for 5 ml swallows and 10 mm for 30 ml swallows; emptying time was 1.2-2.2 s for 5 ml swallows (BFT was 0.3-3 s) and 3.25-3.75 s for 30 ml swallows; DI was 2.4-3.4 mm
conclusionsThe 4D manometry system facilitates a comprehensive characterization of dynamic esophageal bolus transit with concurrent luminal morphology and pressure from conventional HRIM measurements. Calculations of flow rate and wall distensibility provide novel measures of EGJ functionality.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.