ArticleScientific reports2020

Validation of the BD FACSPresto system for the measurement of CD4 T-lymphocytes and hemoglobin concentration in HIV-negative and HIV-positive subjects.

Xiaofan Lu, Hanxiao Sun, Haicong Li, Wei Xia, Hao Wu, Daihong Chen, Meiyu Tan, Shijun Yu, Tong Zhang, Huiming Sheng and 1 more

Abstract readComparative StudyMulticenter StudyValidation Study
In one paragraph

Article in Scientific reports, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Clinical Application Evaluation of ElecsysFrontiers in cellular and infection microbiology · 2022
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Xiaofan LuCenter for Infectious Diseases, Beijing Youan Hospital, Capital Medical University, Beijing, China.
Hanxiao SunShanghai Tong Ren Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
Haicong LiShanghai Public Health Clinical Center, Fudan University, Shanghai, China.
Wei XiaCenter for Infectious Diseases, Beijing Youan Hospital, Capital Medical University, Beijing, China.
Hao WuCenter for Infectious Diseases, Beijing Youan Hospital, Capital Medical University, Beijing, China.
Daihong ChenShanghai Public Health Clinical Center, Fudan University, Shanghai, China.
Meiyu TanShanghai Tong Ren Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
Shijun YuBD Biosciences, 2350 Qume Drive, San Jose, CA, 95131, USA.
Tong ZhangCenter for Infectious Diseases, Beijing Youan Hospital, Capital Medical University, Beijing, China. zt_doc@ccmu.edu.cn.
Huiming ShengShanghai Tong Ren Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China. hmsheng@shsmu.edu.cn.
Zhaoqin ZhuShanghai Public Health Clinical Center, Fudan University, Shanghai, China. zhaoqinzhu@163.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study aimed to compare the performance of the BD FACSPresto system with the conventional standard-of-care technologies for the measurement of absolute CD4 count (AbsCD4), CD4 percentage (CD4%) and total hemoglobin concentration (Hb) in capillary and venous blood samples of HIV-negative and HIV-positive subjects. A total of 1304 participants were included in this prospective cohort study. Both venous and capillary blood samples were analyzed using the BD FACSPresto system and the results were compared against the BD FACSCalibur for enumerating AbsCD4 and CD4% and Sysmex XT-4000i hematology analyzer for determining Hb levels. Method comparison studies were performed using Deming regression and Bland-Altman plots. The Deming regression analyses comparing the accuracy of the BD FACSPresto system with the reference standard technologies demonstrated a significant linear correlation between the AbsCD4, CD4%, and Hb values generated by the two platforms. The 95% CI of the slopes for AbsCD4, CD4%, and Hb levels were 0.94-0.99, 0.99-1.01 and 0.86-0.93, respectively (P < 0.001). Bland-Altman plots for AbsCD4, CD4%, and Hb levels demonstrated close agreement between the BD FACSPresto system and the reference standards for all study participants. The performance and accuracy of BD FACSPresto system was comparable to the reference standard technologies. The BD FACSPresto system can be used interchangeably with BD FACSCalibur platform for CD4 and Sysmex XT-4000i hematology analyzer for Hb concentrations in resource-limited settings thus, improving accessibility to point-of-care testing services.

Indexed as

CD4 Lymphocyte CountAdultFemaleFlow CytometryHemoglobinsHIV InfectionsHIV SeropositivityHumansMalePoint-of-Care SystemsPregnancyProspective StudiesHemoglobins

Identifiers

PMID33177659
PMCPMC7658244

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.